Wideband resistive voltage divider for a standard wattmeter
Resumen:
This work shows the state of development of resistive voltage dividers for use in a standard wattmeter that covers a frequency range from 50 Hz to 100 kHz. The voltage ranges go from 4 V to 1024 V with an expected accuracy of 20 μV/V and 60 μrad/kHz. Nonlinear influences are studied and different methods to compensate the effect of stray capacitances are analysed, as well as the measurement systems used to calibrate these devices