Soil-Structure interaction of a building with a foundation slab with the static models of Winkler and Pasternak

Interacción Suelo-Estructura de una edificación con losa de cimentación con los modelos estáticos de Winkler y Pasternak

Interação solo-estrutura de uma edificação com laje de fundação com os modelos estáticos de Winkler e Pasternak

Contreras, Juan - Villarreal Castro, Genner
Detalles Bibliográficos
2025
Interacción suelo estructura
Modelos estáticos de Winkler y Pasternak
Coeficientes de rigidez del suelo
Soil-structure interaction
Static Winkler and Pasternak soil models
Soil stiffness coefficients
Interação solo-estrutura
Modelos estáticos de solo de Winkler e Pasternak
Coeficientes de rigidez do solo
Español
Universidad de Montevideo
REDUM
http://revistas.um.edu.uy/index.php/ingenieria/article/view/1553
https://hdl.handle.net/20.500.12806/2729
Acceso abierto
Atribución 4.0 Internacional
Resumen:
Sumario:Winkler and Pasternak established that the soil-structure interaction between the base of a structure and the foundation soil can be idealized as a set of stiffness springs that move as a result of the load applied to its surface (Ubani, 2022). The contribution of static models is the incorporation of the dynamic properties of the soil through linear elastic soil behavior models, facilitating the calculation procedures based on the mechanical properties obtained from the foundation soil stratum. By incorporating the static coefficients obtained with the elastic properties of the soil, in a structural model it is possible to verify if there may be any variation in the structural behavior of the model (Villarreal, 2017). In this aspect, the research arose with the objective of determining if these variations can be significant in affecting the structural behavior of the building that has a foundation slab as a foundation. For this purpose, the soil properties obtained from a soil mechanics study (SMS) were considered, through which it was determined that the soil is categorized as S3, with an elasticity modulus E_s=1150 ton/m2, Poisson coefficient υ=0.30 and height of the stratum in the study area. The seismic zone was determined as an acceleration zone with 0.25g. The results were obtained from the comparison of the model with earthquake-resistant design that considers as part of its parameters that the foundation soil is non-deformable, and the models with the SSI coefficients of Winkler and Pasternak. Through the results, it was concluded that there is a significant increase in the shear stresses at the level that is in direct contact with the foundation slab, while the variation in the fundamental period and the lateral deformation of the building was not significant, considering in part that the structure is highly rigid due to its structural system of shear walls.