Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel

Impacto del diámetro en la distribución de la presión alrededor de una elipse en un arreglo de barras cilíndricas paralelas para diferentes ángulos de inclinación respecto a un flujo de aire en un canal rectangular

Ferrari, Hernán - Marino, Raúl - Herrero, Víctor
Detalles Bibliográficos
2021
Flujo de aire
Flujo transversal
Obstáculos cilíndricos
Distribución de presión
Desprendimiento de flujo
Air flow
Yawed flow
Cylindrical obstacle
Pressure distribution
Flow detachment
Español
Universidad de Montevideo
REDUM
http://revistas.um.edu.uy/index.php/ingenieria/article/view/859
Acceso abierto
Atribución 4.0 Internacional
_version_ 1807356689094017024
author Ferrari, Hernán
author2 Marino, Raúl
Herrero, Víctor
author2_role author
author
author_facet Ferrari, Hernán
Marino, Raúl
Herrero, Víctor
author_role author
collection REDUM
dc.creator.none.fl_str_mv Ferrari, Hernán
Marino, Raúl
Herrero, Víctor
dc.date.none.fl_str_mv 2021-12-15
dc.description.en-US.fl_txt_mv The experimental study of the pressure distribution around an obstacle formed by four cylindrical tubes of three different diameters immersed in a transversal flow and at different inclination angles with respect to the flow was carried out. Air at atmospheric pressure was used with a maximum flow of 0.038 Kg / sec. For each cylinder bore and spacing, the pressure distribution is strongly influenced by the angle of inclination, but only marginally affected by flow (within the working range). Due to the turbulent condition of the air flow, with a Reynolds number in the separation between bars from 1695 to 5100, a very good agreement was obtained between the experimental results and a model based on the average air speed in that space, better than a model based on the curvature of streamlines in the gap.
dc.description.es-ES.fl_txt_mv Se realizó el estudio experimental de la distribución de presión alrededor de un obstáculo formado por cuatro tubos cilíndricos de tres diámetros diferentes inmerso en un flujo transversal y a distintos ángulos de inclinación respecto al flujo. Se utilizó aire a presión atmosférica con flujo máximo de 0.038 kg/seg. Para cada diámetro y separación entre cilindros, la distribución de presión alrededor del obstáculo está fuertemente influenciado por el ángulo de inclinación, pero solo marginalmente afectado por el caudal (dentro del rango de trabajo). Debido a la condición de turbulencia del flujo de aire, con un número de Reynolds en la separación entre barras de 1695 a 5100, se obtuvo una muy buena concordancia entre los resultados experimentales y un modelo basado en la velocidad media del aire en ese espacio, mejor que un modelo basado en la curvatura de las líneas de corriente.
dc.format.none.fl_str_mv application/pdf
dc.identifier.none.fl_str_mv http://revistas.um.edu.uy/index.php/ingenieria/article/view/859
10.36561/ING.21.6
dc.language.iso.none.fl_str_mv spa
dc.publisher.es-ES.fl_str_mv Universidad de Montevideo
dc.relation.none.fl_str_mv http://revistas.um.edu.uy/index.php/ingenieria/article/view/859/1062
dc.rights.es-ES.fl_str_mv Derechos de autor 2021 Hernán Ferrari, Raúl Marino, Víctor Herrero
http://creativecommons.org/licenses/by/4.0
dc.rights.license.none.fl_str_mv Atribución 4.0 Internacional
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.en-US.fl_str_mv Memoria Investigaciones en Ingeniería; No. 21 (2021); 56-70
dc.source.es-ES.fl_str_mv Memoria Investigaciones en Ingeniería; Núm. 21 (2021); 56-70
dc.source.none.fl_str_mv 2301-1106
2301-1092
10.36561/ING.21
reponame:REDUM
instname:Universidad de Montevideo
instacron:Universidad de Montevideo
dc.source.pt-BR.fl_str_mv Memoria Investigaciones en Ingenieria; n. 21 (2021); 56-70
dc.subject.en-US.fl_str_mv Air flow
Yawed flow
Cylindrical obstacle
Pressure distribution
Flow detachment
dc.subject.es-ES.fl_str_mv Flujo de aire
Flujo transversal
Obstáculos cilíndricos
Distribución de presión
Desprendimiento de flujo
dc.title.none.fl_str_mv Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
Impacto del diámetro en la distribución de la presión alrededor de una elipse en un arreglo de barras cilíndricas paralelas para diferentes ángulos de inclinación respecto a un flujo de aire en un canal rectangular
dc.type.en-US.fl_str_mv Peer reviewed articles
dc.type.es-ES.fl_str_mv Artículos evaluados por pares
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
dc.type.pt-BR.fl_str_mv Artigos revistos por pares
dc.type.version.none.fl_str_mv publishedVersion
info:eu-repo/semantics/publishedVersion
description The experimental study of the pressure distribution around an obstacle formed by four cylindrical tubes of three different diameters immersed in a transversal flow and at different inclination angles with respect to the flow was carried out. Air at atmospheric pressure was used with a maximum flow of 0.038 Kg / sec. For each cylinder bore and spacing, the pressure distribution is strongly influenced by the angle of inclination, but only marginally affected by flow (within the working range). Due to the turbulent condition of the air flow, with a Reynolds number in the separation between bars from 1695 to 5100, a very good agreement was obtained between the experimental results and a model based on the average air speed in that space, better than a model based on the curvature of streamlines in the gap.
eu_rights_str_mv openAccess
format article
id REDUM_0d94c93d81081059c28796ff553c8827
identifier_str_mv 10.36561/ING.21.6
instacron_str Universidad de Montevideo
institution Universidad de Montevideo
instname_str Universidad de Montevideo
language spa
network_acronym_str REDUM
network_name_str REDUM
oai_identifier_str oai:redum.um.edu.uy:20.500.12806/2561
publishDate 2021
reponame_str REDUM
repository.mail.fl_str_mv nolascoaga@um.edu.uy
repository.name.fl_str_mv REDUM - Universidad de Montevideo
repository_id_str 10501
rights_invalid_str_mv Derechos de autor 2021 Hernán Ferrari, Raúl Marino, Víctor Herrero
http://creativecommons.org/licenses/by/4.0
Atribución 4.0 Internacional
spelling Ferrari, HernánMarino, RaúlHerrero, Víctor2021-12-15http://revistas.um.edu.uy/index.php/ingenieria/article/view/85910.36561/ING.21.6The experimental study of the pressure distribution around an obstacle formed by four cylindrical tubes of three different diameters immersed in a transversal flow and at different inclination angles with respect to the flow was carried out. Air at atmospheric pressure was used with a maximum flow of 0.038 Kg / sec. For each cylinder bore and spacing, the pressure distribution is strongly influenced by the angle of inclination, but only marginally affected by flow (within the working range). Due to the turbulent condition of the air flow, with a Reynolds number in the separation between bars from 1695 to 5100, a very good agreement was obtained between the experimental results and a model based on the average air speed in that space, better than a model based on the curvature of streamlines in the gap.Se realizó el estudio experimental de la distribución de presión alrededor de un obstáculo formado por cuatro tubos cilíndricos de tres diámetros diferentes inmerso en un flujo transversal y a distintos ángulos de inclinación respecto al flujo. Se utilizó aire a presión atmosférica con flujo máximo de 0.038 kg/seg. Para cada diámetro y separación entre cilindros, la distribución de presión alrededor del obstáculo está fuertemente influenciado por el ángulo de inclinación, pero solo marginalmente afectado por el caudal (dentro del rango de trabajo). Debido a la condición de turbulencia del flujo de aire, con un número de Reynolds en la separación entre barras de 1695 a 5100, se obtuvo una muy buena concordancia entre los resultados experimentales y un modelo basado en la velocidad media del aire en ese espacio, mejor que un modelo basado en la curvatura de las líneas de corriente.application/pdfspaUniversidad de Montevideohttp://revistas.um.edu.uy/index.php/ingenieria/article/view/859/1062Derechos de autor 2021 Hernán Ferrari, Raúl Marino, Víctor Herrerohttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAtribución 4.0 InternacionalMemoria Investigaciones en Ingeniería; No. 21 (2021); 56-70Memoria Investigaciones en Ingeniería; Núm. 21 (2021); 56-70Memoria Investigaciones en Ingenieria; n. 21 (2021); 56-702301-11062301-109210.36561/ING.21reponame:REDUMinstname:Universidad de Montevideoinstacron:Universidad de MontevideoFlujo de aireFlujo transversalObstáculos cilíndricosDistribución de presiónDesprendimiento de flujoAir flowYawed flowCylindrical obstaclePressure distributionFlow detachmentImpact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channelImpacto del diámetro en la distribución de la presión alrededor de una elipse en un arreglo de barras cilíndricas paralelas para diferentes ángulos de inclinación respecto a un flujo de aire en un canal rectangularinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer reviewed articlesArtículos evaluados por paresArtigos revistos por parespublishedVersioninfo:eu-repo/semantics/publishedVersion20.500.12806/25612024-07-17 09:46:44.308oai:redum.um.edu.uy:20.500.12806/2561Universidadhttps://um.edu.uy/https://redum.um.edu.uy/oai/requestnolascoaga@um.edu.uyUruguayopendoar:105012024-07-17T12:46:44REDUM - Universidad de Montevideofalse
spellingShingle Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
Ferrari, Hernán
Flujo de aire
Flujo transversal
Obstáculos cilíndricos
Distribución de presión
Desprendimiento de flujo
Air flow
Yawed flow
Cylindrical obstacle
Pressure distribution
Flow detachment
status_str publishedVersion
title Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
title_full Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
title_fullStr Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
title_full_unstemmed Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
title_short Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
title_sort Impact of diameter on the distribution of pressure around an ellipse in an arrangement of parallel cylindrical bars for different angles of inclination with respect to an air flow in a rectangular channel
topic Flujo de aire
Flujo transversal
Obstáculos cilíndricos
Distribución de presión
Desprendimiento de flujo
Air flow
Yawed flow
Cylindrical obstacle
Pressure distribution
Flow detachment
url http://revistas.um.edu.uy/index.php/ingenieria/article/view/859