Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab
Análisis y diseño sísmico de una edificación multifamiliar de diez niveles y dos sótanos aplicando la interacción suelo-estructura con un sistema dual y platea de cimentación
Análise comparativa de metodologias de pré-dimensionamento de colunas em edifício de seis níveis sem cave
2024 | |
Análisis sísmico Suposición de base fija Sistema dual Seismic analysis Fixed base assumption Dual system Soil-structure interaction Análise sísmica Suposição de base fixa Sistema dual Interação solo-estrutura |
|
Español | |
Universidad de Montevideo | |
REDUM | |
http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285 | |
Acceso abierto | |
Atribución 4.0 Internacional |
_version_ | 1807356688836067328 |
---|---|
author | Quispe, Bladimir |
author2 | Carcausto Vega, Edson Bruner Villarreal, Genner |
author2_role | author author |
author_facet | Quispe, Bladimir Carcausto Vega, Edson Bruner Villarreal, Genner |
author_role | author |
collection | REDUM |
dc.creator.none.fl_str_mv | Quispe, Bladimir Carcausto Vega, Edson Bruner Villarreal, Genner |
dc.date.none.fl_str_mv | 2024-07-03 |
dc.description.en-US.fl_txt_mv | The present investigation is developed with the purpose of determining the influence of the seismic interaction in a building with respect to a building with perfect embedment. The building to be modeled is a reinforced concrete building with a dual system, whose structure consists of 10 levels and two basements, and a foundation slab which is located in the city of Arequipa, district of Yura. Generally, when performing seismic analysis of different buildings, a perfect embedment is assumed. This is particularly adequate as long as the type of soil is hard rock or very stiff soils, as opposed to other types of soils that would not present these qualities for a perfect embedment analysis. In this investigation, the influence of soil-structure interaction is evaluated, which is why the ETABS 2016 program is used to perform the modeling, and the building is modeled to comply with the provisions of the Technical Standard E.030 of Seismic Resistant Design. Subsequently, the structure is analyzed, taking into consideration the application of the dynamic models of D.D. Barkan - O.A. Savinov, Russian Standard SNIP 2.02.05-87, A.E. Sargsian and N.G. Shariya. Finally, it is concluded that, from the results obtained when carrying out the analysis with the assumption of a fixed base versus the soil-structure interaction model, the fundamental periods, the displacement in the X and Y directions, the distortions, the shear stresses in the base, the internal forces of the structural elements, suffer an impact on the result of each of them. |
dc.description.es-ES.fl_txt_mv | La presente investigación se desarrolla con la finalidad de determinar la influencia de la interacción sísmica en una edificación con respecto a una edificación con suposición de base fija. El edificio a modelar es de concreto armado con un sistema dual, cuya estructura está conformada por 10 niveles y dos sótanos, y una platea de cimentación la cual está ubicada en la ciudad de Arequipa, distrito de Yura. Generalmente al realizar los análisis sísmicos de diferentes edificaciones se asume una suposición de base fija. Esta constituye particularmente adecuada siempre y cuando el tipo de suelo sea el de un tipo de roca dura a diferencia de otros tipos de suelos que no presentarían estas cualidades para un análisis con suposición de base fija. En la investigación se evalúa la influencia de la interacción suelo – estructura, es por esto que para la realización del modelamiento se utiliza el programa ETABS 2016, se procede a realizar un modelamiento de la edificación y a su vez esta cumpla lo establecido en la Norma Técnica E.030 de Diseño Sismorresistente. Posterior a esto se analiza la estructura, tomando en consideración la aplicación de los modelos dinámicos de D.D. Barkan – O.A. Savinov, Norma Rusa SNIP 2.02.05-87, A.E. Sargsian y N.G. Shariya. Finalmente se concluye que, de los resultados obtenidos al realizar el análisis con la suposición de base fija versus el modelo de interacción suelo-estructura, los periodos fundamentales, el desplazamiento en las direcciones X e Y, las distorsiones, los esfuerzos cortantes en la base, las fuerzas internas de los elementos estructurales sufren un impacto en el resultado de cada uno de ellos. |
dc.description.pt-BR.fl_txt_mv | A presente investigação desenvolve-se com o objectivo de determinar a influência da interacção sísmica num edifício relativamente a um edifício com hipótese de base fixa. O edifício a modelar é de concreto armado de sistema duplo, cuja estrutura é composta por 10 níveis e dois subsolos, e uma laje de fundação que está localizada na cidade de Arequipa, distrito de Yura. Geralmente, ao realizar análises sísmicas de diferentes edifícios, assume-se uma suposição de base fixa. Isto é particularmente adequado desde que o tipo de solo seja um tipo de rocha dura, ao contrário de outros tipos de solo que não apresentariam estas qualidades para uma análise com uma suposição de base fixa. Na pesquisa é avaliada a influência da interação solo-estrutura, por isso é utilizado o programa ETABS 2016 para realizar a modelagem. O edifício é modelado e por sua vez atende ao disposto na Norma Técnica E.030. -Design resistente. Depois disso, a estrutura é analisada, levando em consideração a aplicação dos modelos dinâmicos de D.D. Barkan – O.A. Savinov, padrão russo SNIP 2.02.05-87, A.E. Sargsian e N.G. Sharia. Por fim, conclui-se que, a partir dos resultados obtidos ao realizar a análise com pressuposto de base fixa versus modelo de interação solo-estrutura, foram identificados os períodos fundamentais, o deslocamento nas direções X e Y, as distorções, as tensões de cisalhamento na base, as forças internas dos elementos estruturais impactam no resultado de cada um deles. |
dc.format.none.fl_str_mv | application/pdf text/html |
dc.identifier.none.fl_str_mv | http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285 10.36561/ING.26.10 |
dc.language.iso.none.fl_str_mv | spa |
dc.publisher.es-ES.fl_str_mv | Universidad de Montevideo |
dc.relation.none.fl_str_mv | http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285/1681 http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285/1682 |
dc.rights.es-ES.fl_str_mv | Derechos de autor 2024 Bladimir Quispe, Edison Carcausto, Genner Villarreal http://creativecommons.org/licenses/by/4.0 |
dc.rights.license.none.fl_str_mv | Atribución 4.0 Internacional |
dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
dc.source.en-US.fl_str_mv | Memoria Investigaciones en Ingeniería; No. 26 (2024); 158-187 |
dc.source.es-ES.fl_str_mv | Memoria Investigaciones en Ingeniería; Núm. 26 (2024); 158-187 |
dc.source.none.fl_str_mv | 2301-1106 2301-1092 10.36561/ING.26 reponame:REDUM instname:Universidad de Montevideo instacron:Universidad de Montevideo |
dc.source.pt-BR.fl_str_mv | Memoria Investigaciones en Ingenieria; n. 26 (2024); 158-187 |
dc.subject.en-US.fl_str_mv | Seismic analysis Fixed base assumption Dual system Soil-structure interaction |
dc.subject.es-ES.fl_str_mv | Análisis sísmico Suposición de base fija Sistema dual |
dc.subject.pt-BR.fl_str_mv | Análise sísmica Suposição de base fixa Sistema dual Interação solo-estrutura |
dc.title.none.fl_str_mv | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab Análisis y diseño sísmico de una edificación multifamiliar de diez niveles y dos sótanos aplicando la interacción suelo-estructura con un sistema dual y platea de cimentación Análise comparativa de metodologias de pré-dimensionamento de colunas em edifício de seis níveis sem cave |
dc.type.en-US.fl_str_mv | Peer reviewed articles |
dc.type.es-ES.fl_str_mv | Artículos evaluados por pares |
dc.type.none.fl_str_mv | info:eu-repo/semantics/article info:eu-repo/semantics/publishedVersion |
dc.type.pt-BR.fl_str_mv | Artigos revistos por pares |
dc.type.version.none.fl_str_mv | publishedVersion info:eu-repo/semantics/publishedVersion |
description | The present investigation is developed with the purpose of determining the influence of the seismic interaction in a building with respect to a building with perfect embedment. The building to be modeled is a reinforced concrete building with a dual system, whose structure consists of 10 levels and two basements, and a foundation slab which is located in the city of Arequipa, district of Yura. Generally, when performing seismic analysis of different buildings, a perfect embedment is assumed. This is particularly adequate as long as the type of soil is hard rock or very stiff soils, as opposed to other types of soils that would not present these qualities for a perfect embedment analysis. In this investigation, the influence of soil-structure interaction is evaluated, which is why the ETABS 2016 program is used to perform the modeling, and the building is modeled to comply with the provisions of the Technical Standard E.030 of Seismic Resistant Design. Subsequently, the structure is analyzed, taking into consideration the application of the dynamic models of D.D. Barkan - O.A. Savinov, Russian Standard SNIP 2.02.05-87, A.E. Sargsian and N.G. Shariya. Finally, it is concluded that, from the results obtained when carrying out the analysis with the assumption of a fixed base versus the soil-structure interaction model, the fundamental periods, the displacement in the X and Y directions, the distortions, the shear stresses in the base, the internal forces of the structural elements, suffer an impact on the result of each of them. |
eu_rights_str_mv | openAccess |
format | article |
id | REDUM_0b29f105c1aac256ddf1a505083f561e |
identifier_str_mv | 10.36561/ING.26.10 |
instacron_str | Universidad de Montevideo |
institution | Universidad de Montevideo |
instname_str | Universidad de Montevideo |
language | spa |
network_acronym_str | REDUM |
network_name_str | REDUM |
oai_identifier_str | oai:redum.um.edu.uy:20.500.12806/2616 |
publishDate | 2024 |
reponame_str | REDUM |
repository.mail.fl_str_mv | nolascoaga@um.edu.uy |
repository.name.fl_str_mv | REDUM - Universidad de Montevideo |
repository_id_str | 10501 |
rights_invalid_str_mv | Derechos de autor 2024 Bladimir Quispe, Edison Carcausto, Genner Villarreal http://creativecommons.org/licenses/by/4.0 Atribución 4.0 Internacional |
spelling | Quispe, BladimirCarcausto Vega, Edson BrunerVillarreal, Genner2024-07-03http://revistas.um.edu.uy/index.php/ingenieria/article/view/128510.36561/ING.26.10The present investigation is developed with the purpose of determining the influence of the seismic interaction in a building with respect to a building with perfect embedment. The building to be modeled is a reinforced concrete building with a dual system, whose structure consists of 10 levels and two basements, and a foundation slab which is located in the city of Arequipa, district of Yura. Generally, when performing seismic analysis of different buildings, a perfect embedment is assumed. This is particularly adequate as long as the type of soil is hard rock or very stiff soils, as opposed to other types of soils that would not present these qualities for a perfect embedment analysis. In this investigation, the influence of soil-structure interaction is evaluated, which is why the ETABS 2016 program is used to perform the modeling, and the building is modeled to comply with the provisions of the Technical Standard E.030 of Seismic Resistant Design. Subsequently, the structure is analyzed, taking into consideration the application of the dynamic models of D.D. Barkan - O.A. Savinov, Russian Standard SNIP 2.02.05-87, A.E. Sargsian and N.G. Shariya. Finally, it is concluded that, from the results obtained when carrying out the analysis with the assumption of a fixed base versus the soil-structure interaction model, the fundamental periods, the displacement in the X and Y directions, the distortions, the shear stresses in the base, the internal forces of the structural elements, suffer an impact on the result of each of them.La presente investigación se desarrolla con la finalidad de determinar la influencia de la interacción sísmica en una edificación con respecto a una edificación con suposición de base fija. El edificio a modelar es de concreto armado con un sistema dual, cuya estructura está conformada por 10 niveles y dos sótanos, y una platea de cimentación la cual está ubicada en la ciudad de Arequipa, distrito de Yura. Generalmente al realizar los análisis sísmicos de diferentes edificaciones se asume una suposición de base fija. Esta constituye particularmente adecuada siempre y cuando el tipo de suelo sea el de un tipo de roca dura a diferencia de otros tipos de suelos que no presentarían estas cualidades para un análisis con suposición de base fija. En la investigación se evalúa la influencia de la interacción suelo – estructura, es por esto que para la realización del modelamiento se utiliza el programa ETABS 2016, se procede a realizar un modelamiento de la edificación y a su vez esta cumpla lo establecido en la Norma Técnica E.030 de Diseño Sismorresistente. Posterior a esto se analiza la estructura, tomando en consideración la aplicación de los modelos dinámicos de D.D. Barkan – O.A. Savinov, Norma Rusa SNIP 2.02.05-87, A.E. Sargsian y N.G. Shariya. Finalmente se concluye que, de los resultados obtenidos al realizar el análisis con la suposición de base fija versus el modelo de interacción suelo-estructura, los periodos fundamentales, el desplazamiento en las direcciones X e Y, las distorsiones, los esfuerzos cortantes en la base, las fuerzas internas de los elementos estructurales sufren un impacto en el resultado de cada uno de ellos.A presente investigação desenvolve-se com o objectivo de determinar a influência da interacção sísmica num edifício relativamente a um edifício com hipótese de base fixa. O edifício a modelar é de concreto armado de sistema duplo, cuja estrutura é composta por 10 níveis e dois subsolos, e uma laje de fundação que está localizada na cidade de Arequipa, distrito de Yura. Geralmente, ao realizar análises sísmicas de diferentes edifícios, assume-se uma suposição de base fixa. Isto é particularmente adequado desde que o tipo de solo seja um tipo de rocha dura, ao contrário de outros tipos de solo que não apresentariam estas qualidades para uma análise com uma suposição de base fixa. Na pesquisa é avaliada a influência da interação solo-estrutura, por isso é utilizado o programa ETABS 2016 para realizar a modelagem. O edifício é modelado e por sua vez atende ao disposto na Norma Técnica E.030. -Design resistente. Depois disso, a estrutura é analisada, levando em consideração a aplicação dos modelos dinâmicos de D.D. Barkan – O.A. Savinov, padrão russo SNIP 2.02.05-87, A.E. Sargsian e N.G. Sharia. Por fim, conclui-se que, a partir dos resultados obtidos ao realizar a análise com pressuposto de base fixa versus modelo de interação solo-estrutura, foram identificados os períodos fundamentais, o deslocamento nas direções X e Y, as distorções, as tensões de cisalhamento na base, as forças internas dos elementos estruturais impactam no resultado de cada um deles.application/pdftext/htmlspaUniversidad de Montevideohttp://revistas.um.edu.uy/index.php/ingenieria/article/view/1285/1681http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285/1682Derechos de autor 2024 Bladimir Quispe, Edison Carcausto, Genner Villarrealhttp://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessAtribución 4.0 InternacionalMemoria Investigaciones en Ingeniería; No. 26 (2024); 158-187Memoria Investigaciones en Ingeniería; Núm. 26 (2024); 158-187Memoria Investigaciones en Ingenieria; n. 26 (2024); 158-1872301-11062301-109210.36561/ING.26reponame:REDUMinstname:Universidad de Montevideoinstacron:Universidad de MontevideoAnálisis sísmicoSuposición de base fijaSistema dualSeismic analysisFixed base assumptionDual systemSoil-structure interactionAnálise sísmicaSuposição de base fixaSistema dualInteração solo-estruturaSeismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation SlabAnálisis y diseño sísmico de una edificación multifamiliar de diez niveles y dos sótanos aplicando la interacción suelo-estructura con un sistema dual y platea de cimentaciónAnálise comparativa de metodologias de pré-dimensionamento de colunas em edifício de seis níveis sem caveinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionPeer reviewed articlesArtículos evaluados por paresArtigos revistos por parespublishedVersioninfo:eu-repo/semantics/publishedVersion20.500.12806/26162024-07-17 09:54:11.502oai:redum.um.edu.uy:20.500.12806/2616Universidadhttps://um.edu.uy/https://redum.um.edu.uy/oai/requestnolascoaga@um.edu.uyUruguayopendoar:105012024-07-17T12:54:11REDUM - Universidad de Montevideofalse |
spellingShingle | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab Quispe, Bladimir Análisis sísmico Suposición de base fija Sistema dual Seismic analysis Fixed base assumption Dual system Soil-structure interaction Análise sísmica Suposição de base fixa Sistema dual Interação solo-estrutura |
status_str | publishedVersion |
title | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
title_full | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
title_fullStr | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
title_full_unstemmed | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
title_short | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
title_sort | Seismic Analysis and Design of a Ten-Story, Two-Basement Multifamily Building Using Soil-Structure Interaction with a Dual System and Foundation Slab |
topic | Análisis sísmico Suposición de base fija Sistema dual Seismic analysis Fixed base assumption Dual system Soil-structure interaction Análise sísmica Suposição de base fixa Sistema dual Interação solo-estrutura |
url | http://revistas.um.edu.uy/index.php/ingenieria/article/view/1285 |