Module for stimuli control of an integrated programmable current source for implantable medical devices

Martínez, Natalia

Supervisor(es): Míguez, Matías

Resumen:

Implantable Medical Devices (IMDs) have been widely deployed in both novel and established applications. Ranging from cardiac defibrillators, pacemakers and cochlear implants to gastric and neurostimulators, these devices are being improved through the developments in microelectronics, biotechnology, medicine and materials. In this work, two multipurpose integrated current generators for IMDs designed by the Microelectronics Group at the Universidad Católica del Uruguay are fully characterized and validated. These current sources are capable of extracting and delivering a wide range of outputs from hundreds of μA to tens of mA making them suitable for different clinical applications. The measured parameters include the output current range and precision, supply voltage range, output voltage range, bias current dependence, response times, current consumption and crosstalk. The second part of this project consists of the design of a calibration module to be appended to the current sources. The purpose of this module is to detect any current mismatch between the sourcing and sinking stimulation phases which can lead to tissue damage over time. Once measured, the current difference can be reduced by means of the trimming mechanism integrated in the current sources’ design. The calibration module was implemented as a Switched-Capacitor (SC) amplifier and was submitted for manufacturing in XFAB’s XT018 180nm CMOS technology. The circuit can also be easily adapted to function as an Electrode-Tissue Interface (ETI) impedance measurement device.


Los Dispositivos Médicos Implantables (IMDs, por su sigla en inglés) han tenido un amplio desarrollo en sus aplicaciones originales y en nuevas áreas. Desde desfibriladores cardíacos, marcapasos e implantes cocleares hasta neuroestimuladores y estimuladores gástricos, estos dispositivos están siendo mejorados a través de los avances en microelectrónica, biotecnología, medicina y materiales. En este trabajo se realiza la caracterización completa y validación de dos generadores de corriente integrados multipropósito para IMDs diseñados por el Grupo de Microelectrónica de la Universidad Católica del Uruguay. Las fuentes son capaces de extraer y entregar un amplio rango de corrientes desde cientos de μA hasta decenas de mA, lo que las hace adecuadas para diferentes aplicaciones médicas. Se midieron parámetros tales como el rango y precisión en la corriente de salida, rango de tensión de alimentación, rango de tensión de salida, dependencia con la corriente de polarización, tiempos de respuesta, consumo de corriente y diafonía. La segunda parte de este proyecto consiste en el diseño de un módulo de calibración para incorporar a las fuentes de corriente. El propósito de este módulo es detectar diferencias entre la corriente inyectada y extraída que con el tiempo pueda conducir a daños en el tejido biológico. Una vez medida, es posible actuar para reducirla mediante el mecanismo de ajuste fino integrado en el diseño de las fuentes de corriente. El módulo de calibración se implementó como un amplificador con Capacitores Conmutados (SC, por su sigla en inglés) y se envió a fabricar en la tecnología CMOS XT018 de 180nm de XFAB. El circuito puede ser adaptado fácilmente para funcionar como un dispositivo de medición de impedancia de la interfaz electrodo-tejido (ETI, por su sigla en inglés).


Detalles Bibliográficos
2022
Fuente de corriente
Circuitos integrados
Microelectrónica
Dispositivos médicos implantables
Memoria de grado (Ingeniería en electrónica)
Inglés
Universidad Católica del Uruguay
LIBERI
https://hdl.handle.net/10895/1624
Acceso abierto
Licencia Creative Commons Atribución – No Comercial – Sin Derivadas (CC BY-NC-ND 4.0)
_version_ 1815178685893836800
author Martínez, Natalia
author_facet Martínez, Natalia
author_role author
bitstream.checksum.fl_str_mv 5526f4c3fd46c34c5cc294df4ab3107f
8a4605be74aa9ea9d79846c1fba20a33
cb25dac238c79d45d95f33d2416e8427
e3470c2c3ba952f29f64c475577318eb
ba8abb8fa0f65122104b868e1b143ad4
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
bitstream.url.fl_str_mv http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/1/Martinez2022.pdf
http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/2/license.txt
http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/3/Captura.JPG
http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/5/Martinez2022.pdf.jpg
http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/4/Martinez2022.pdf.txt
collection LIBERI
dc.creator.advisor.none.fl_str_mv Míguez, Matías
dc.creator.none.fl_str_mv Martínez, Natalia
dc.date.accessioned.none.fl_str_mv 2022-03-11T17:23:14Z
dc.date.available.none.fl_str_mv 2022-03-11T17:23:14Z
dc.date.issued.none.fl_str_mv 2022-03-02
dc.description.abstract.none.fl_txt_mv Implantable Medical Devices (IMDs) have been widely deployed in both novel and established applications. Ranging from cardiac defibrillators, pacemakers and cochlear implants to gastric and neurostimulators, these devices are being improved through the developments in microelectronics, biotechnology, medicine and materials. In this work, two multipurpose integrated current generators for IMDs designed by the Microelectronics Group at the Universidad Católica del Uruguay are fully characterized and validated. These current sources are capable of extracting and delivering a wide range of outputs from hundreds of μA to tens of mA making them suitable for different clinical applications. The measured parameters include the output current range and precision, supply voltage range, output voltage range, bias current dependence, response times, current consumption and crosstalk. The second part of this project consists of the design of a calibration module to be appended to the current sources. The purpose of this module is to detect any current mismatch between the sourcing and sinking stimulation phases which can lead to tissue damage over time. Once measured, the current difference can be reduced by means of the trimming mechanism integrated in the current sources’ design. The calibration module was implemented as a Switched-Capacitor (SC) amplifier and was submitted for manufacturing in XFAB’s XT018 180nm CMOS technology. The circuit can also be easily adapted to function as an Electrode-Tissue Interface (ETI) impedance measurement device.
Los Dispositivos Médicos Implantables (IMDs, por su sigla en inglés) han tenido un amplio desarrollo en sus aplicaciones originales y en nuevas áreas. Desde desfibriladores cardíacos, marcapasos e implantes cocleares hasta neuroestimuladores y estimuladores gástricos, estos dispositivos están siendo mejorados a través de los avances en microelectrónica, biotecnología, medicina y materiales. En este trabajo se realiza la caracterización completa y validación de dos generadores de corriente integrados multipropósito para IMDs diseñados por el Grupo de Microelectrónica de la Universidad Católica del Uruguay. Las fuentes son capaces de extraer y entregar un amplio rango de corrientes desde cientos de μA hasta decenas de mA, lo que las hace adecuadas para diferentes aplicaciones médicas. Se midieron parámetros tales como el rango y precisión en la corriente de salida, rango de tensión de alimentación, rango de tensión de salida, dependencia con la corriente de polarización, tiempos de respuesta, consumo de corriente y diafonía. La segunda parte de este proyecto consiste en el diseño de un módulo de calibración para incorporar a las fuentes de corriente. El propósito de este módulo es detectar diferencias entre la corriente inyectada y extraída que con el tiempo pueda conducir a daños en el tejido biológico. Una vez medida, es posible actuar para reducirla mediante el mecanismo de ajuste fino integrado en el diseño de las fuentes de corriente. El módulo de calibración se implementó como un amplificador con Capacitores Conmutados (SC, por su sigla en inglés) y se envió a fabricar en la tecnología CMOS XT018 de 180nm de XFAB. El circuito puede ser adaptado fácilmente para funcionar como un dispositivo de medición de impedancia de la interfaz electrodo-tejido (ETI, por su sigla en inglés).
dc.format.extent.es.fl_str_mv 105 p.
dc.format.mimetype.none.fl_str_mv application/pdf
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/10895/1624
dc.language.iso.none.fl_str_mv eng
dc.publisher.es.fl_str_mv Universidad Católica del Uruguay
dc.rights.license.none.fl_str_mv Licencia Creative Commons Atribución – No Comercial – Sin Derivadas (CC BY-NC-ND 4.0)
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:LIBERI
instname:Universidad Católica del Uruguay
instacron:Universidad Católica del Uruguay
dc.subject.es.fl_str_mv Fuente de corriente
Circuitos integrados
Microelectrónica
Dispositivos médicos implantables
Memoria de grado (Ingeniería en electrónica)
dc.title.none.fl_str_mv Module for stimuli control of an integrated programmable current source for implantable medical devices
dc.type.es.fl_str_mv Trabajo final de grado
dc.type.none.fl_str_mv info:eu-repo/semantics/bachelorThesis
dc.type.version.none.fl_str_mv info:eu-repo/semantics/acceptedVersion
description Implantable Medical Devices (IMDs) have been widely deployed in both novel and established applications. Ranging from cardiac defibrillators, pacemakers and cochlear implants to gastric and neurostimulators, these devices are being improved through the developments in microelectronics, biotechnology, medicine and materials. In this work, two multipurpose integrated current generators for IMDs designed by the Microelectronics Group at the Universidad Católica del Uruguay are fully characterized and validated. These current sources are capable of extracting and delivering a wide range of outputs from hundreds of μA to tens of mA making them suitable for different clinical applications. The measured parameters include the output current range and precision, supply voltage range, output voltage range, bias current dependence, response times, current consumption and crosstalk. The second part of this project consists of the design of a calibration module to be appended to the current sources. The purpose of this module is to detect any current mismatch between the sourcing and sinking stimulation phases which can lead to tissue damage over time. Once measured, the current difference can be reduced by means of the trimming mechanism integrated in the current sources’ design. The calibration module was implemented as a Switched-Capacitor (SC) amplifier and was submitted for manufacturing in XFAB’s XT018 180nm CMOS technology. The circuit can also be easily adapted to function as an Electrode-Tissue Interface (ETI) impedance measurement device.
eu_rights_str_mv openAccess
format bachelorThesis
id LIBERI_bf1bd7dc60a61f986ce7c822e28a0b22
instacron_str Universidad Católica del Uruguay
institution Universidad Católica del Uruguay
instname_str Universidad Católica del Uruguay
language eng
network_acronym_str LIBERI
network_name_str LIBERI
oai_identifier_str oai:liberi.ucu.edu.uy:10895/1624
publishDate 2022
reponame_str LIBERI
repository.mail.fl_str_mv franco.pertusso@ucu.edu.uy
repository.name.fl_str_mv LIBERI - Universidad Católica del Uruguay
repository_id_str 10342
rights_invalid_str_mv Licencia Creative Commons Atribución – No Comercial – Sin Derivadas (CC BY-NC-ND 4.0)
spelling Licencia Creative Commons Atribución – No Comercial – Sin Derivadas (CC BY-NC-ND 4.0)info:eu-repo/semantics/openAccess2022-03-11T17:23:14Z2022-03-11T17:23:14Z2022-03-02https://hdl.handle.net/10895/1624Implantable Medical Devices (IMDs) have been widely deployed in both novel and established applications. Ranging from cardiac defibrillators, pacemakers and cochlear implants to gastric and neurostimulators, these devices are being improved through the developments in microelectronics, biotechnology, medicine and materials. In this work, two multipurpose integrated current generators for IMDs designed by the Microelectronics Group at the Universidad Católica del Uruguay are fully characterized and validated. These current sources are capable of extracting and delivering a wide range of outputs from hundreds of μA to tens of mA making them suitable for different clinical applications. The measured parameters include the output current range and precision, supply voltage range, output voltage range, bias current dependence, response times, current consumption and crosstalk. The second part of this project consists of the design of a calibration module to be appended to the current sources. The purpose of this module is to detect any current mismatch between the sourcing and sinking stimulation phases which can lead to tissue damage over time. Once measured, the current difference can be reduced by means of the trimming mechanism integrated in the current sources’ design. The calibration module was implemented as a Switched-Capacitor (SC) amplifier and was submitted for manufacturing in XFAB’s XT018 180nm CMOS technology. The circuit can also be easily adapted to function as an Electrode-Tissue Interface (ETI) impedance measurement device.Los Dispositivos Médicos Implantables (IMDs, por su sigla en inglés) han tenido un amplio desarrollo en sus aplicaciones originales y en nuevas áreas. Desde desfibriladores cardíacos, marcapasos e implantes cocleares hasta neuroestimuladores y estimuladores gástricos, estos dispositivos están siendo mejorados a través de los avances en microelectrónica, biotecnología, medicina y materiales. En este trabajo se realiza la caracterización completa y validación de dos generadores de corriente integrados multipropósito para IMDs diseñados por el Grupo de Microelectrónica de la Universidad Católica del Uruguay. Las fuentes son capaces de extraer y entregar un amplio rango de corrientes desde cientos de μA hasta decenas de mA, lo que las hace adecuadas para diferentes aplicaciones médicas. Se midieron parámetros tales como el rango y precisión en la corriente de salida, rango de tensión de alimentación, rango de tensión de salida, dependencia con la corriente de polarización, tiempos de respuesta, consumo de corriente y diafonía. La segunda parte de este proyecto consiste en el diseño de un módulo de calibración para incorporar a las fuentes de corriente. El propósito de este módulo es detectar diferencias entre la corriente inyectada y extraída que con el tiempo pueda conducir a daños en el tejido biológico. Una vez medida, es posible actuar para reducirla mediante el mecanismo de ajuste fino integrado en el diseño de las fuentes de corriente. El módulo de calibración se implementó como un amplificador con Capacitores Conmutados (SC, por su sigla en inglés) y se envió a fabricar en la tecnología CMOS XT018 de 180nm de XFAB. El circuito puede ser adaptado fácilmente para funcionar como un dispositivo de medición de impedancia de la interfaz electrodo-tejido (ETI, por su sigla en inglés).105 p.application/pdfUniversidad Católica del UruguayFuente de corrienteCircuitos integradosMicroelectrónicaDispositivos médicos implantablesMemoria de grado (Ingeniería en electrónica)Module for stimuli control of an integrated programmable current source for implantable medical devicesTrabajo final de gradoinfo:eu-repo/semantics/bachelorThesisinfo:eu-repo/semantics/acceptedVersionreponame:LIBERIinstname:Universidad Católica del Uruguayinstacron:Universidad Católica del UruguayMartínez, NataliaMíguez, MatíasengORIGINALMartinez2022.pdfMartinez2022.pdfapplication/pdf4060576http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/1/Martinez2022.pdf5526f4c3fd46c34c5cc294df4ab3107fMD51LICENSElicense.txtlicense.txttext/plain; charset=utf-81748http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/2/license.txt8a4605be74aa9ea9d79846c1fba20a33MD52THUMBNAILCaptura.JPGCaptura.JPGimage/jpeg14457http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/3/Captura.JPGcb25dac238c79d45d95f33d2416e8427MD53Martinez2022.pdf.jpgMartinez2022.pdf.jpgGenerated Thumbnailimage/jpeg3746http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/5/Martinez2022.pdf.jpge3470c2c3ba952f29f64c475577318ebMD55TEXTMartinez2022.pdf.txtMartinez2022.pdf.txtExtracted texttext/plain136603http://liberi.ucu.edu.uy/xmlui/bitstream/10895/1624/4/Martinez2022.pdf.txtba8abb8fa0f65122104b868e1b143ad4MD5410895/16242022-03-13 00:01:34.3oai:liberi.ucu.edu.uy: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Universidadhttps://www.ucu.edu.uy/https://liberi.ucu.edu.uy/oai/requestfranco.pertusso@ucu.edu.uyUruguayopendoar:103422022-03-13T03:01:34LIBERI - Universidad Católica del Uruguayfalse
spellingShingle Module for stimuli control of an integrated programmable current source for implantable medical devices
Martínez, Natalia
Fuente de corriente
Circuitos integrados
Microelectrónica
Dispositivos médicos implantables
Memoria de grado (Ingeniería en electrónica)
status_str acceptedVersion
title Module for stimuli control of an integrated programmable current source for implantable medical devices
title_full Module for stimuli control of an integrated programmable current source for implantable medical devices
title_fullStr Module for stimuli control of an integrated programmable current source for implantable medical devices
title_full_unstemmed Module for stimuli control of an integrated programmable current source for implantable medical devices
title_short Module for stimuli control of an integrated programmable current source for implantable medical devices
title_sort Module for stimuli control of an integrated programmable current source for implantable medical devices
topic Fuente de corriente
Circuitos integrados
Microelectrónica
Dispositivos médicos implantables
Memoria de grado (Ingeniería en electrónica)
url https://hdl.handle.net/10895/1624