Calibration and Maintenance of Low Power Laser Devices: Descriptive Study

Calibración y mantenimiento de aparatos de láser de baja potencia: estudio descriptivo

Calibragem e manutenção de dispositivos laser de baixa potência: estudo descritivo

Benítez, Ernesto - Ferreiro, María del Carmen
Detalles Bibliográficos
2022
low-level light therapy
calibration
biomedical technology assessment
terapia por luz de baja intensidad
calibración
evaluación de la tecnología biomédica
terapia com luz de baixa intensidade
calibragem
avaliação da tecnologia biomédica
Español
Universidad Católica del Uruguay
LIBERI
https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855
https://hdl.handle.net/10895/3768
Acceso abierto
_version_ 1815178708133085184
author Benítez, Ernesto
author2 Ferreiro, María del Carmen
author2_role author
author_facet Benítez, Ernesto
Ferreiro, María del Carmen
author_role author
collection LIBERI
dc.creator.none.fl_str_mv Benítez, Ernesto
Ferreiro, María del Carmen
dc.date.accessioned.none.fl_str_mv 2023-09-13T12:42:38Z
dc.date.available.none.fl_str_mv 2023-09-13T12:42:38Z
dc.date.none.fl_str_mv 2022-11-01
dc.description.en-US.fl_txt_mv Introduction: The low-power laser is a technique used in several areas of health: physiotherapy, dentistry, otorhinolaryngology and dermatology, among others. To achieve therapeutic effects, the dosage is essential and depends on the energy levels emitted by the device. Objective: To know the status of calibration and maintenance of low power laser therapy devices, in physiotherapy services or counterparts of institutions in Montevideo - Uruguay. Method: A descriptive, cross-sectional study was conducted in physiotherapy services in Montevideo, Uruguay. 20 low-power laser devices were analyzed. Results: 7 of the devices evaluated remained within the appropriate emission limits. Of the 13 lasers outside the limits to deliver adequate emission, 6 had a slight mismatch, 1 had a moderate mismatch, and 6 presented a severe mismatch. Among the total devices evaluated, only 6 had performed a previous calibration and only 2 of these were within the recommended times frames. Conclusion: A large number of low-power laser devices with imbalances in their emission was observed. In most cases, low-power laser devices are not properly maintained. Equipment should be timely calibrated in order to offer safe and effective therapy to users.
dc.description.es-ES.fl_txt_mv Introducción: El láser de baja potencia es una técnica utilizada en varias áreas de la salud: fisioterapia, odontología, otorrinolaringología y dermatología, entre otras. Para lograr los efectos terapéuticos la dosificación es fundamental y depende de los niveles de energía emitidos por los equipos. Objetivo: Conocer el estado de calibración y mantenimiento de los equipos de laserterapia de baja potencia, en servicios de fisioterapia u homólogos de instituciones de Montevideo, Uruguay. Método: Se realizó un estudio descriptivo, transversal en servicios de fisioterapia de Montevideo. Se analizaron 20 equipos de láser de baja potencia. Resultados: 7 de los aparatos evaluados se mantuvieron dentro de los límites adecuados de emisión. De los 13 láser fuera de los límites para entregar una emisión adecuada, 6 tenían un desajuste leve, 1 presentaba un desajuste moderado y 6 presentaban un desajuste severo con dosis nulas o que no generaban emisión. Del total de equipos evaluados solo 6 habían realizado una calibración previa y solo 2 de estos se encontraban dentro de los tiempos recomendados. Conclusión: Se observó un gran número de equipos de láser de baja potencia con desajustes en su emisión. En la mayoría de los casos no se lleva un correcto mantenimiento de los aparatos de láser de baja potencia. Se entiende relevante que los equipos sean calibrados para poder ofrecer una terapéutica segura y efectiva a los usuarios.
dc.description.pt-PT.fl_txt_mv Introdução: O laser de baixa potência é uma técnica utilizada em diversas áreas da saúde: fisioterapia, odontologia, otorrinolaringologia, dermatologia, dentre outras. Para obter efeitos terapêuticos, a dosagem é essencial e depende dos níveis de energia emitidos pelo equipamento. Objetivo: conhecer o estado de calibração e manutenção de equipamentos de laserterapia de baixa potência, em serviços de fisioterapia ou congêneres de instituições em Montevideu - Uruguai. Método: estudo descritivo, transversal, realizado em serviços de fisioterapia em Montevideo, Uruguai. 20 equipamentos de laser de baixa potência foram analisados. Resultados: 7 dos aparelhos avaliados permaneceram dentro dos limites de emissão adequados. Dos 13 lasers fora dos limites para entregar a emissão adequada, 6 tiveram uma leve incompatibilidade, 1 teve uma incompatibilidade moderada e 6 apresentaram uma incompatibilidade grave. Do total de equipamentos avaliados, apenas 6 haviam realizado uma calibragem prévia e apenas 2 destes estavam dentro do prazo recomendado (1 ano). Conclusão: observou-se um grande número de equipamentos de laser de baixa potência com desequilíbrios em sua emissão. Na maioria dos casos, os dispositivos a laser de baixa potência não recebem manutenção adequada. Acredita-se importante que os equipamentos sejam calibrados para oferecer uma terapia segura e eficaz aos usuários.
dc.format.none.fl_str_mv application/pdf
application/pdf
dc.identifier.none.fl_str_mv https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855
10.22235/ech.v11i2.2855
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/10895/3768
dc.language.iso.none.fl_str_mv spa
eng
dc.publisher.es-ES.fl_str_mv Universidad Católica del Uruguay
dc.relation.none.fl_str_mv https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855/2694
https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855/2695
dc.rights.es-ES.fl_str_mv Derechos de autor 2022 Enfermería: Cuidados Humanizados
https://creativecommons.org/licenses/by/4.0
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.en-US.fl_str_mv Enfermería: Cuidados Humanizados; Vol. 11 No. 2 (2022): Enfermería: Cuidados Humanizados; e2855
dc.source.es-ES.fl_str_mv Enfermería: Cuidados Humanizados; Vol. 11 Núm. 2 (2022): Enfermería: Cuidados Humanizados; e2855
dc.source.none.fl_str_mv 2393-6606
1688-8375
10.22235/ech.v11i2
reponame:LIBERI
instname:Universidad Católica del Uruguay
instacron:Universidad Católica del Uruguay
dc.source.pt-PT.fl_str_mv Enfermería: Cuidados Humanizados; Vol. 11 N.º 2 (2022): Enfermería: Cuidados Humanizados; e2855
dc.subject.en-US.fl_str_mv low-level light therapy
calibration
biomedical technology assessment
dc.subject.es-ES.fl_str_mv terapia por luz de baja intensidad
calibración
evaluación de la tecnología biomédica
dc.subject.pt-PT.fl_str_mv terapia com luz de baixa intensidade
calibragem
avaliação da tecnologia biomédica
dc.title.none.fl_str_mv Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
Calibración y mantenimiento de aparatos de láser de baja potencia: estudio descriptivo
Calibragem e manutenção de dispositivos laser de baixa potência: estudo descritivo
dc.type.none.fl_str_mv info:eu-repo/semantics/article
info:eu-repo/semantics/publishedVersion
dc.type.version.none.fl_str_mv info:eu-repo/semantics/publishedVersion
description Introduction: The low-power laser is a technique used in several areas of health: physiotherapy, dentistry, otorhinolaryngology and dermatology, among others. To achieve therapeutic effects, the dosage is essential and depends on the energy levels emitted by the device. Objective: To know the status of calibration and maintenance of low power laser therapy devices, in physiotherapy services or counterparts of institutions in Montevideo - Uruguay. Method: A descriptive, cross-sectional study was conducted in physiotherapy services in Montevideo, Uruguay. 20 low-power laser devices were analyzed. Results: 7 of the devices evaluated remained within the appropriate emission limits. Of the 13 lasers outside the limits to deliver adequate emission, 6 had a slight mismatch, 1 had a moderate mismatch, and 6 presented a severe mismatch. Among the total devices evaluated, only 6 had performed a previous calibration and only 2 of these were within the recommended times frames. Conclusion: A large number of low-power laser devices with imbalances in their emission was observed. In most cases, low-power laser devices are not properly maintained. Equipment should be timely calibrated in order to offer safe and effective therapy to users.
eu_rights_str_mv openAccess
format article
id LIBERI_089d0d0d0ad4ad50a9d1d696f1a58774
identifier_str_mv 10.22235/ech.v11i2.2855
instacron_str Universidad Católica del Uruguay
institution Universidad Católica del Uruguay
instname_str Universidad Católica del Uruguay
language spa
eng
network_acronym_str LIBERI
network_name_str LIBERI
oai_identifier_str oai:liberi.ucu.edu.uy:10895/3768
publishDate 2022
reponame_str LIBERI
repository.mail.fl_str_mv franco.pertusso@ucu.edu.uy
repository.name.fl_str_mv LIBERI - Universidad Católica del Uruguay
repository_id_str 10342
rights_invalid_str_mv Derechos de autor 2022 Enfermería: Cuidados Humanizados
https://creativecommons.org/licenses/by/4.0
spelling Benítez, ErnestoFerreiro, María del Carmen2022-11-012023-09-13T12:42:38Z2023-09-13T12:42:38Zhttps://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/285510.22235/ech.v11i2.2855https://hdl.handle.net/10895/3768Introduction: The low-power laser is a technique used in several areas of health: physiotherapy, dentistry, otorhinolaryngology and dermatology, among others. To achieve therapeutic effects, the dosage is essential and depends on the energy levels emitted by the device. Objective: To know the status of calibration and maintenance of low power laser therapy devices, in physiotherapy services or counterparts of institutions in Montevideo - Uruguay. Method: A descriptive, cross-sectional study was conducted in physiotherapy services in Montevideo, Uruguay. 20 low-power laser devices were analyzed. Results: 7 of the devices evaluated remained within the appropriate emission limits. Of the 13 lasers outside the limits to deliver adequate emission, 6 had a slight mismatch, 1 had a moderate mismatch, and 6 presented a severe mismatch. Among the total devices evaluated, only 6 had performed a previous calibration and only 2 of these were within the recommended times frames. Conclusion: A large number of low-power laser devices with imbalances in their emission was observed. In most cases, low-power laser devices are not properly maintained. Equipment should be timely calibrated in order to offer safe and effective therapy to users.Introducción: El láser de baja potencia es una técnica utilizada en varias áreas de la salud: fisioterapia, odontología, otorrinolaringología y dermatología, entre otras. Para lograr los efectos terapéuticos la dosificación es fundamental y depende de los niveles de energía emitidos por los equipos. Objetivo: Conocer el estado de calibración y mantenimiento de los equipos de laserterapia de baja potencia, en servicios de fisioterapia u homólogos de instituciones de Montevideo, Uruguay. Método: Se realizó un estudio descriptivo, transversal en servicios de fisioterapia de Montevideo. Se analizaron 20 equipos de láser de baja potencia. Resultados: 7 de los aparatos evaluados se mantuvieron dentro de los límites adecuados de emisión. De los 13 láser fuera de los límites para entregar una emisión adecuada, 6 tenían un desajuste leve, 1 presentaba un desajuste moderado y 6 presentaban un desajuste severo con dosis nulas o que no generaban emisión. Del total de equipos evaluados solo 6 habían realizado una calibración previa y solo 2 de estos se encontraban dentro de los tiempos recomendados. Conclusión: Se observó un gran número de equipos de láser de baja potencia con desajustes en su emisión. En la mayoría de los casos no se lleva un correcto mantenimiento de los aparatos de láser de baja potencia. Se entiende relevante que los equipos sean calibrados para poder ofrecer una terapéutica segura y efectiva a los usuarios.Introdução: O laser de baixa potência é uma técnica utilizada em diversas áreas da saúde: fisioterapia, odontologia, otorrinolaringologia, dermatologia, dentre outras. Para obter efeitos terapêuticos, a dosagem é essencial e depende dos níveis de energia emitidos pelo equipamento. Objetivo: conhecer o estado de calibração e manutenção de equipamentos de laserterapia de baixa potência, em serviços de fisioterapia ou congêneres de instituições em Montevideu - Uruguai. Método: estudo descritivo, transversal, realizado em serviços de fisioterapia em Montevideo, Uruguai. 20 equipamentos de laser de baixa potência foram analisados. Resultados: 7 dos aparelhos avaliados permaneceram dentro dos limites de emissão adequados. Dos 13 lasers fora dos limites para entregar a emissão adequada, 6 tiveram uma leve incompatibilidade, 1 teve uma incompatibilidade moderada e 6 apresentaram uma incompatibilidade grave. Do total de equipamentos avaliados, apenas 6 haviam realizado uma calibragem prévia e apenas 2 destes estavam dentro do prazo recomendado (1 ano). Conclusão: observou-se um grande número de equipamentos de laser de baixa potência com desequilíbrios em sua emissão. Na maioria dos casos, os dispositivos a laser de baixa potência não recebem manutenção adequada. Acredita-se importante que os equipamentos sejam calibrados para oferecer uma terapia segura e eficaz aos usuários.application/pdfapplication/pdfspaengUniversidad Católica del Uruguayhttps://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855/2694https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855/2695Derechos de autor 2022 Enfermería: Cuidados Humanizadoshttps://creativecommons.org/licenses/by/4.0info:eu-repo/semantics/openAccessEnfermería: Cuidados Humanizados; Vol. 11 No. 2 (2022): Enfermería: Cuidados Humanizados; e2855Enfermería: Cuidados Humanizados; Vol. 11 Núm. 2 (2022): Enfermería: Cuidados Humanizados; e2855Enfermería: Cuidados Humanizados; Vol. 11 N.º 2 (2022): Enfermería: Cuidados Humanizados; e28552393-66061688-837510.22235/ech.v11i2reponame:LIBERIinstname:Universidad Católica del Uruguayinstacron:Universidad Católica del Uruguaylow-level light therapycalibrationbiomedical technology assessmentterapia por luz de baja intensidadcalibraciónevaluación de la tecnología biomédicaterapia com luz de baixa intensidadecalibragemavaliação da tecnologia biomédicaCalibration and Maintenance of Low Power Laser Devices: Descriptive StudyCalibración y mantenimiento de aparatos de láser de baja potencia: estudio descriptivoCalibragem e manutenção de dispositivos laser de baixa potência: estudo descritivoinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersioninfo:eu-repo/semantics/publishedVersion10895/37682023-09-13 09:42:38.352oai:liberi.ucu.edu.uy:10895/3768Universidadhttps://www.ucu.edu.uy/https://liberi.ucu.edu.uy/oai/requestfranco.pertusso@ucu.edu.uyUruguayopendoar:103422023-09-13T12:42:38LIBERI - Universidad Católica del Uruguayfalse
spellingShingle Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
Benítez, Ernesto
low-level light therapy
calibration
biomedical technology assessment
terapia por luz de baja intensidad
calibración
evaluación de la tecnología biomédica
terapia com luz de baixa intensidade
calibragem
avaliação da tecnologia biomédica
status_str publishedVersion
title Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
title_full Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
title_fullStr Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
title_full_unstemmed Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
title_short Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
title_sort Calibration and Maintenance of Low Power Laser Devices: Descriptive Study
topic low-level light therapy
calibration
biomedical technology assessment
terapia por luz de baja intensidad
calibración
evaluación de la tecnología biomédica
terapia com luz de baixa intensidade
calibragem
avaliação da tecnologia biomédica
url https://revistas.ucu.edu.uy/index.php/enfermeriacuidadoshumanizados/article/view/2855
https://hdl.handle.net/10895/3768