Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water
Resumen:
SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance – Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices.
2017 | |
AGUA POTABLE ELEMENTOS TRAZA MÉTODOS ANALÍTICOS METROLOGÍA |
|
Inglés | |
Laboratorio Tecnológico del Uruguay | |
Catálogo digital del LATU | |
https://catalogo.latu.org.uy/opac_css/index.php?lvl=notice_display&id=31956 | |
Acceso abierto | |
CC BY-NC-ND |
_version_ | 1807353831172866048 |
---|---|
author | YANG, LU |
author2 | NADEAU, KENNY GEDARA PIHILLAGAWA, INDU MEIJA, JURIS GRINBERG, PATRICIA MESTER, ZOLTAN VALLE MOYA, EDITH SOLÍS GONZÁLEZ, FAVIOLA ALEJANDRA ARVIZU TORRES, MARÍA DEL ROCÍO YAÑEZ MUÑOZ, OSCAR VELINA LARA-MANZANO, JUDITH MAZZITELLO, GISELA PRINA, PEDRO ACOSTA, OSVALDO NAPOLI, ROMINA PÉREZ, RAMIRO FERREIRA, ELIZABETH DOBROVOLSKIY, VLADIMIR APRELEV, ALEKSEI STAKHEEV, ALKSEI FROLOV, DMITRY GUSEV, LEONID IVANOVA, VERONIKA NÄYKKI, TEEMU SARA-AHO, TIMO VENEGAS PADILLA, JIMMY ACUÑA CUBILLO, CARLOS BREMMER, DWYTE FREEMANTEL, RUEL TAEBUNPAKUL, SUTTHINUN TANGPAISARNKUL, NONGLUCK RODRUANGTHUM, PATUMPORN KAEWKHOMDEE, NATTIKARN THIENGMANEE, USANA TANGJIT, TARARAT BUZOIANU, MIRELLA MARÍA AHUMADA FORIGUA, DIEJO ALEJANDRO ABELLA GAMBA, JOHANNA PAOLA CHAVARRO MEDINA, LUIS ALFREDO SOBINA, EGOR TABATCHIKOVA, TATYANA ALEXOPOULOS, CHARALAMBOS KAKOULIDES, ELIAS DELGADO, MABEL FLORES, LILIANA KNOX, SAIRA SIWLAL, KESTER MAHARAJ, AVINASH |
author2_role | author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author author |
author_facet | YANG, LU NADEAU, KENNY GEDARA PIHILLAGAWA, INDU MEIJA, JURIS GRINBERG, PATRICIA MESTER, ZOLTAN VALLE MOYA, EDITH SOLÍS GONZÁLEZ, FAVIOLA ALEJANDRA ARVIZU TORRES, MARÍA DEL ROCÍO YAÑEZ MUÑOZ, OSCAR VELINA LARA-MANZANO, JUDITH MAZZITELLO, GISELA PRINA, PEDRO ACOSTA, OSVALDO NAPOLI, ROMINA PÉREZ, RAMIRO FERREIRA, ELIZABETH DOBROVOLSKIY, VLADIMIR APRELEV, ALEKSEI STAKHEEV, ALKSEI FROLOV, DMITRY GUSEV, LEONID IVANOVA, VERONIKA NÄYKKI, TEEMU SARA-AHO, TIMO VENEGAS PADILLA, JIMMY ACUÑA CUBILLO, CARLOS BREMMER, DWYTE FREEMANTEL, RUEL TAEBUNPAKUL, SUTTHINUN TANGPAISARNKUL, NONGLUCK RODRUANGTHUM, PATUMPORN KAEWKHOMDEE, NATTIKARN THIENGMANEE, USANA TANGJIT, TARARAT BUZOIANU, MIRELLA MARÍA AHUMADA FORIGUA, DIEJO ALEJANDRO ABELLA GAMBA, JOHANNA PAOLA CHAVARRO MEDINA, LUIS ALFREDO SOBINA, EGOR TABATCHIKOVA, TATYANA ALEXOPOULOS, CHARALAMBOS KAKOULIDES, ELIAS DELGADO, MABEL FLORES, LILIANA KNOX, SAIRA SIWLAL, KESTER MAHARAJ, AVINASH |
author_role | author |
collection | Catálogo digital del LATU |
dc.coverage.none.fl_str_mv | En: Metrologia, 2018, 55, 08002 |
dc.creator.none.fl_str_mv | YANG, LU NADEAU, KENNY GEDARA PIHILLAGAWA, INDU MEIJA, JURIS GRINBERG, PATRICIA MESTER, ZOLTAN VALLE MOYA, EDITH SOLÍS GONZÁLEZ, FAVIOLA ALEJANDRA ARVIZU TORRES, MARÍA DEL ROCÍO YAÑEZ MUÑOZ, OSCAR VELINA LARA-MANZANO, JUDITH MAZZITELLO, GISELA PRINA, PEDRO ACOSTA, OSVALDO NAPOLI, ROMINA PÉREZ, RAMIRO FERREIRA, ELIZABETH DOBROVOLSKIY, VLADIMIR APRELEV, ALEKSEI STAKHEEV, ALKSEI FROLOV, DMITRY GUSEV, LEONID IVANOVA, VERONIKA NÄYKKI, TEEMU SARA-AHO, TIMO VENEGAS PADILLA, JIMMY ACUÑA CUBILLO, CARLOS BREMMER, DWYTE FREEMANTEL, RUEL TAEBUNPAKUL, SUTTHINUN TANGPAISARNKUL, NONGLUCK RODRUANGTHUM, PATUMPORN KAEWKHOMDEE, NATTIKARN THIENGMANEE, USANA TANGJIT, TARARAT BUZOIANU, MIRELLA MARÍA AHUMADA FORIGUA, DIEJO ALEJANDRO ABELLA GAMBA, JOHANNA PAOLA CHAVARRO MEDINA, LUIS ALFREDO SOBINA, EGOR TABATCHIKOVA, TATYANA ALEXOPOULOS, CHARALAMBOS KAKOULIDES, ELIAS DELGADO, MABEL FLORES, LILIANA KNOX, SAIRA SIWLAL, KESTER MAHARAJ, AVINASH |
dc.date.none.fl_str_mv | 2017-01-01 |
dc.description.abstract.none.fl_txt_mv | SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance – Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. |
dc.format.none.fl_str_mv | Pdf |
dc.identifier.none.fl_str_mv | https://catalogo.latu.org.uy/opac_css/index.php?lvl=notice_display&id=31956 31956 urn:ISBN:69076 |
dc.language.iso.none.fl_str_mv | eng |
dc.rights.license.none.fl_str_mv | CC BY-NC-ND |
dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess CC BY-NC-ND |
dc.source.none.fl_str_mv | reponame:Catálogo digital del LATU instname:Laboratorio Tecnológico del Uruguay instacron:Laboratorio Tecnológico del Uruguay |
dc.subject.none.fl_str_mv | AGUA POTABLE ELEMENTOS TRAZA MÉTODOS ANALÍTICOS METROLOGÍA |
dc.title.none.fl_str_mv | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
dc.type.none.fl_str_mv | info:eu-repo/semantics/article Publicado |
dc.type.version.none.fl_str_mv | info:eu-repo/semantics/publishedVersion |
description | SIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance – Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices. |
eu_rights_str_mv | openAccess |
format | article |
id | LATU_f915ad3442d8aae7b3e3fb7698b82555 |
identifier_str_mv | 31956 urn:ISBN:69076 |
instacron_str | Laboratorio Tecnológico del Uruguay |
institution | Laboratorio Tecnológico del Uruguay |
instname_str | Laboratorio Tecnológico del Uruguay |
language | eng |
network_acronym_str | LATU |
network_name_str | Catálogo digital del LATU |
oai_identifier_str | oai:PMBOAI:31956 |
publishDate | 2017 |
reponame_str | Catálogo digital del LATU |
repository.mail.fl_str_mv | lfiori@latu.org.uy |
repository.name.fl_str_mv | Catálogo digital del LATU - Laboratorio Tecnológico del Uruguay |
repository_id_str | |
rights_invalid_str_mv | CC BY-NC-ND CC BY-NC-ND |
spelling | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking waterYANG, LUNADEAU, KENNYGEDARA PIHILLAGAWA, INDUMEIJA, JURISGRINBERG, PATRICIAMESTER, ZOLTANVALLE MOYA, EDITHSOLÍS GONZÁLEZ, FAVIOLA ALEJANDRAARVIZU TORRES, MARÍA DEL ROCÍOYAÑEZ MUÑOZ, OSCARVELINA LARA-MANZANO, JUDITHMAZZITELLO, GISELAPRINA, PEDROACOSTA, OSVALDONAPOLI, ROMINAPÉREZ, RAMIROFERREIRA, ELIZABETHDOBROVOLSKIY, VLADIMIRAPRELEV, ALEKSEISTAKHEEV, ALKSEIFROLOV, DMITRYGUSEV, LEONIDIVANOVA, VERONIKANÄYKKI, TEEMUSARA-AHO, TIMOVENEGAS PADILLA, JIMMYACUÑA CUBILLO, CARLOSBREMMER, DWYTEFREEMANTEL, RUELTAEBUNPAKUL, SUTTHINUNTANGPAISARNKUL, NONGLUCKRODRUANGTHUM, PATUMPORNKAEWKHOMDEE, NATTIKARNTHIENGMANEE, USANATANGJIT, TARARATBUZOIANU, MIRELLA MARÍAAHUMADA FORIGUA, DIEJO ALEJANDROABELLA GAMBA, JOHANNA PAOLACHAVARRO MEDINA, LUIS ALFREDOSOBINA, EGORTABATCHIKOVA, TATYANAALEXOPOULOS, CHARALAMBOSKAKOULIDES, ELIASDELGADO, MABELFLORES, LILIANAKNOX, SAIRASIWLAL, KESTERMAHARAJ, AVINASHAGUA POTABLEELEMENTOS TRAZAMÉTODOS ANALÍTICOSMETROLOGÍASIM.QM-S7 was performed to assess the analytical capabilities of National Metrology Institutes (NMIs) and Designated Institutes (DIs) of SIM members (or other regions) for the accurate determination of trace metals in drinking water. The study was proposed by the coordinating laboratories National Research Council Canada (NRC) and Centro Nacional de Metrologia (CENAM) as an activity of Inorganic Analysis Working Group (IAWG) of Consultative Committee for Amount of Substance – Metrology in Chemistry and Biology (CCQM). Participants included 16 NMIs/DIs from 15 countries. No measurement method was prescribed by the coordinating laboratories. Therefore, NMIs used measurement methods of their choice. However, the majority of NMIs/DIs used ICP-MS. This SIM.QM-S7 Supplementary Comparison provides NMIs/DIs with the needed evidence for CMC claims for trace elements in fresh waters and similar matrices.2017-01-01info:eu-repo/semantics/articlePublicadoinfo:eu-repo/semantics/publishedVersionPdfhttps://catalogo.latu.org.uy/opac_css/index.php?lvl=notice_display&id=3195631956urn:ISBN:69076engEn: Metrologia, 2018, 55, 08002info:eu-repo/semantics/openAccessCC BY-NC-NDCC BY-NC-NDreponame:Catálogo digital del LATUinstname:Laboratorio Tecnológico del Uruguayinstacron:Laboratorio Tecnológico del Uruguay2020-05-12T17:56:51Zoai:PMBOAI:31956Gobiernohttps://latu.org.uy/https://catalogo.latu.org.uy/ws/PMBOAIlfiori@latu.org.uyUruguayopendoar:2024-08-01T14:48:54.923215Catálogo digital del LATU - Laboratorio Tecnológico del Uruguayfalse |
spellingShingle | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water YANG, LU AGUA POTABLE ELEMENTOS TRAZA MÉTODOS ANALÍTICOS METROLOGÍA |
status_str | publishedVersion |
title | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
title_full | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
title_fullStr | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
title_full_unstemmed | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
title_short | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
title_sort | Final report of the SIM.QM-S7 supplementary comparison : Trace metals in drinking water |
topic | AGUA POTABLE ELEMENTOS TRAZA MÉTODOS ANALÍTICOS METROLOGÍA |
url | https://catalogo.latu.org.uy/opac_css/index.php?lvl=notice_display&id=31956 |