Power estimations vs. Power measurements in Cyclone III devices

Boemo, Eduardo - Oliver, Juan Pablo

Resumen:

This paper presents experimental measurements of power consumption for core logic of a 65-nm Cyclone III FPGA and its comparison with the value predicted by the power estimation tool. The laboratory work is described, including the measurement setup, the benchmark circuits, and the CAD flows utilized to obtain power estimations. The selected circuits used as benchmarks were different type of multipliers implemented in LUTs and in embedded blocks both with or without pipelining stages. Three type of results are presented: first, the error between power measurements and power estimations; second, the power savings by using pipeline stages, and third, the quantification of power savings by using embedded blocks.


Detalles Bibliográficos
2011
Electrónica
Inglés
Universidad de la República
COLIBRI
https://hdl.handle.net/20.500.12008/41155
Acceso abierto
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
Resumen:
Sumario:Trabajo presentado al 2011 VII Southern Conference on Programmable Logic (SPL) Programmable Logic (SPL), 2011 VII Southern Conference on