High-precision current comparator for current transformer calibrations.

Slomovitz, Daniel - Trigo, Leonardo - Santos, Alejandro - Aristoy, Gonzalo

Resumen:

The development and testing of a current comparator (CC) is described. It is intended for ac low frequency applications, such as calibration of instrument current transformers (CT). The CC can be self-calibrated comparing its different inputs between them, without need of an external reference standard. This device was developed to sustain the selftraceability of calibration of CT at UTE (delegated National Metrology Institute of Uruguay).


Detalles Bibliográficos
2013
Current transformer
Current comparator
High precision measurement
Uncertainty
Self-calibration
Traceability
Inglés
Universidad de la República
COLIBRI
https://hdl.handle.net/20.500.12008/25837
Acceso abierto
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
_version_ 1807522896571006976
author Slomovitz, Daniel
author2 Trigo, Leonardo
Santos, Alejandro
Aristoy, Gonzalo
author2_role author
author
author
author_facet Slomovitz, Daniel
Trigo, Leonardo
Santos, Alejandro
Aristoy, Gonzalo
author_role author
bitstream.checksum.fl_str_mv 6429389a7df7277b72b7924fdc7d47a9
a006180e3f5b2ad0b88185d14284c0e0
bb66dcbdf7fd7aa7bce25f3cf50d2042
1996b8461bc290aef6a27d78c67b6b52
f3c00ae19d4deab04bdb2d148acfd14d
bitstream.checksumAlgorithm.fl_str_mv MD5
MD5
MD5
MD5
MD5
bitstream.url.fl_str_mv http://localhost:8080/xmlui/bitstream/20.500.12008/25837/5/license.txt
http://localhost:8080/xmlui/bitstream/20.500.12008/25837/2/license_url
http://localhost:8080/xmlui/bitstream/20.500.12008/25837/3/license_text
http://localhost:8080/xmlui/bitstream/20.500.12008/25837/4/license_rdf
http://localhost:8080/xmlui/bitstream/20.500.12008/25837/1/STSA13.pdf
collection COLIBRI
dc.contributor.filiacion.none.fl_str_mv Slomovitz Daniel, Universidad de la República (Uruguay). Facultad de Ingeniería.
Trigo Leonardo, Laboratorio de UTE
Santos Alejandro, Laboratorio de UTE
Aristoy Gonzalo, Laboratorio de UTE
dc.coverage.spatial.es.fl_str_mv Uruguay
dc.creator.none.fl_str_mv Slomovitz, Daniel
Trigo, Leonardo
Santos, Alejandro
Aristoy, Gonzalo
dc.date.accessioned.none.fl_str_mv 2020-11-09T20:50:10Z
dc.date.available.none.fl_str_mv 2020-11-09T20:50:10Z
dc.date.issued.none.fl_str_mv 2013
dc.description.abstract.none.fl_txt_mv The development and testing of a current comparator (CC) is described. It is intended for ac low frequency applications, such as calibration of instrument current transformers (CT). The CC can be self-calibrated comparing its different inputs between them, without need of an external reference standard. This device was developed to sustain the selftraceability of calibration of CT at UTE (delegated National Metrology Institute of Uruguay).
dc.format.extent.es.fl_str_mv 2 p.
dc.format.mimetype.es.fl_str_mv application/pdf
dc.identifier.citation.es.fl_str_mv Slomovitz, D., Trigo, L., Santos, A. y otros. High-precision current comparator for current transformer calibrations [en línea] EN : X-SEMETRO-2013, 10th International Congress on Electrical Metrology, Instituto Nacional de Tecnología Industrial (INTI), Buenos Aires, Argentina, 25-27 sep. Buenos Aires : SEMETRO, 2013. 2 p.
dc.identifier.uri.none.fl_str_mv https://hdl.handle.net/20.500.12008/25837
dc.language.iso.none.fl_str_mv en
eng
dc.publisher.es.fl_str_mv SEMETRO
dc.relation.ispartof.es.fl_str_mv X-SEMETRO-2013, 10th International Congress on Electrical Metrology, Instituto Nacional de Tecnología Industrial (INTI), Buenos Aires, Argentina, 25-27 sep., p. 1-2.
dc.rights.license.none.fl_str_mv Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
dc.rights.none.fl_str_mv info:eu-repo/semantics/openAccess
dc.source.none.fl_str_mv reponame:COLIBRI
instname:Universidad de la República
instacron:Universidad de la República
dc.subject.en.fl_str_mv Current transformer
Current comparator
High precision measurement
Uncertainty
Self-calibration
Traceability
dc.title.none.fl_str_mv High-precision current comparator for current transformer calibrations.
dc.type.es.fl_str_mv Ponencia
dc.type.none.fl_str_mv info:eu-repo/semantics/conferenceObject
dc.type.version.none.fl_str_mv info:eu-repo/semantics/publishedVersion
description The development and testing of a current comparator (CC) is described. It is intended for ac low frequency applications, such as calibration of instrument current transformers (CT). The CC can be self-calibrated comparing its different inputs between them, without need of an external reference standard. This device was developed to sustain the selftraceability of calibration of CT at UTE (delegated National Metrology Institute of Uruguay).
eu_rights_str_mv openAccess
format conferenceObject
id COLIBRI_d672897a02b0a206d56c843f5e0caaa1
identifier_str_mv Slomovitz, D., Trigo, L., Santos, A. y otros. High-precision current comparator for current transformer calibrations [en línea] EN : X-SEMETRO-2013, 10th International Congress on Electrical Metrology, Instituto Nacional de Tecnología Industrial (INTI), Buenos Aires, Argentina, 25-27 sep. Buenos Aires : SEMETRO, 2013. 2 p.
instacron_str Universidad de la República
institution Universidad de la República
instname_str Universidad de la República
language eng
language_invalid_str_mv en
network_acronym_str COLIBRI
network_name_str COLIBRI
oai_identifier_str oai:colibri.udelar.edu.uy:20.500.12008/25837
publishDate 2013
reponame_str COLIBRI
repository.mail.fl_str_mv mabel.seroubian@seciu.edu.uy
repository.name.fl_str_mv COLIBRI - Universidad de la República
repository_id_str 4771
rights_invalid_str_mv Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
spelling Slomovitz Daniel, Universidad de la República (Uruguay). Facultad de Ingeniería.Trigo Leonardo, Laboratorio de UTESantos Alejandro, Laboratorio de UTEAristoy Gonzalo, Laboratorio de UTEUruguay2020-11-09T20:50:10Z2020-11-09T20:50:10Z2013Slomovitz, D., Trigo, L., Santos, A. y otros. High-precision current comparator for current transformer calibrations [en línea] EN : X-SEMETRO-2013, 10th International Congress on Electrical Metrology, Instituto Nacional de Tecnología Industrial (INTI), Buenos Aires, Argentina, 25-27 sep. Buenos Aires : SEMETRO, 2013. 2 p.https://hdl.handle.net/20.500.12008/25837The development and testing of a current comparator (CC) is described. It is intended for ac low frequency applications, such as calibration of instrument current transformers (CT). The CC can be self-calibrated comparing its different inputs between them, without need of an external reference standard. This device was developed to sustain the selftraceability of calibration of CT at UTE (delegated National Metrology Institute of Uruguay).Submitted by Ribeiro Jorge (jribeiro@fing.edu.uy) on 2020-11-04T21:02:06Z No. of bitstreams: 2 license_rdf: 23149 bytes, checksum: 1996b8461bc290aef6a27d78c67b6b52 (MD5) STSA13.pdf: 614460 bytes, checksum: f3c00ae19d4deab04bdb2d148acfd14d (MD5)Approved for entry into archive by Machado Jimena (jmachado@fing.edu.uy) on 2020-11-09T18:20:12Z (GMT) No. of bitstreams: 2 license_rdf: 23149 bytes, checksum: 1996b8461bc290aef6a27d78c67b6b52 (MD5) STSA13.pdf: 614460 bytes, checksum: f3c00ae19d4deab04bdb2d148acfd14d (MD5)Made available in DSpace by Luna Fabiana (fabiana.luna@fic.edu.uy) on 2020-11-09T20:50:10Z (GMT). No. of bitstreams: 2 license_rdf: 23149 bytes, checksum: 1996b8461bc290aef6a27d78c67b6b52 (MD5) STSA13.pdf: 614460 bytes, checksum: f3c00ae19d4deab04bdb2d148acfd14d (MD5) Previous issue date: 20132 p.application/pdfenengSEMETROX-SEMETRO-2013, 10th International Congress on Electrical Metrology, Instituto Nacional de Tecnología Industrial (INTI), Buenos Aires, Argentina, 25-27 sep., p. 1-2.Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)info:eu-repo/semantics/openAccessLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)Current transformerCurrent comparatorHigh precision measurementUncertaintySelf-calibrationTraceabilityHigh-precision current comparator for current transformer calibrations.Ponenciainfo:eu-repo/semantics/conferenceObjectinfo:eu-repo/semantics/publishedVersionreponame:COLIBRIinstname:Universidad de la Repúblicainstacron:Universidad de la RepúblicaSlomovitz, DanielTrigo, LeonardoSantos, AlejandroAristoy, GonzaloLICENSElicense.txtlicense.txttext/plain; charset=utf-84267http://localhost:8080/xmlui/bitstream/20.500.12008/25837/5/license.txt6429389a7df7277b72b7924fdc7d47a9MD55CC-LICENSElicense_urllicense_urltext/plain; charset=utf-850http://localhost:8080/xmlui/bitstream/20.500.12008/25837/2/license_urla006180e3f5b2ad0b88185d14284c0e0MD52license_textlicense_texttext/html; charset=utf-838695http://localhost:8080/xmlui/bitstream/20.500.12008/25837/3/license_textbb66dcbdf7fd7aa7bce25f3cf50d2042MD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-823149http://localhost:8080/xmlui/bitstream/20.500.12008/25837/4/license_rdf1996b8461bc290aef6a27d78c67b6b52MD54ORIGINALSTSA13.pdfSTSA13.pdfapplication/pdf614460http://localhost:8080/xmlui/bitstream/20.500.12008/25837/1/STSA13.pdff3c00ae19d4deab04bdb2d148acfd14dMD5120.500.12008/258372020-11-09 17:54:47.463oai:colibri.udelar.edu.uy:20.500.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Universidadhttps://udelar.edu.uy/https://www.colibri.udelar.edu.uy/oai/requestmabel.seroubian@seciu.edu.uyUruguayopendoar:47712024-07-25T14:33:08.184792COLIBRI - Universidad de la Repúblicafalse
spellingShingle High-precision current comparator for current transformer calibrations.
Slomovitz, Daniel
Current transformer
Current comparator
High precision measurement
Uncertainty
Self-calibration
Traceability
status_str publishedVersion
title High-precision current comparator for current transformer calibrations.
title_full High-precision current comparator for current transformer calibrations.
title_fullStr High-precision current comparator for current transformer calibrations.
title_full_unstemmed High-precision current comparator for current transformer calibrations.
title_short High-precision current comparator for current transformer calibrations.
title_sort High-precision current comparator for current transformer calibrations.
topic Current transformer
Current comparator
High precision measurement
Uncertainty
Self-calibration
Traceability
url https://hdl.handle.net/20.500.12008/25837