Adaptive output current feedforward control in VR applications
Resumen:
A method for adapting the gain of an output current feedforward path in VR applications is presented. For regulators using adaptive voltage positioning (AVP), output current feedforward can improve the dynamic response to fast load transients. However, the feedforward path depends on parameters of the power train that are not known with precision. By analyzing the error voltage and finding its correlation with the parameter error, a gradient algorithm is derived that makes the parameter error vanish and minimizes the voltage error.
2007 | |
Adaptive control Dynamic response Electric current control Error analysis Feedforward Gradient methods |
|
Inglés | |
Universidad de la República | |
COLIBRI | |
https://hdl.handle.net/20.500.12008/38774 | |
Acceso abierto | |
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) |
Sumario: | Trabajo presentado en IEEE Power Electronics Specialists Conference, 2007 |
---|