Adaptive output current feedforward control in VR applications

Eirea, Gabriel - Sanders, Seth R

Resumen:

A method for adapting the gain of an output current feedforward path in VR applications is presented. For regulators using adaptive voltage positioning (AVP), output current feedforward can improve the dynamic response to fast load transients. However, the feedforward path depends on parameters of the power train that are not known with precision. By analyzing the error voltage and finding its correlation with the parameter error, a gradient algorithm is derived that makes the parameter error vanish and minimizes the voltage error.


Detalles Bibliográficos
2007
Adaptive control
Dynamic response
Electric current control
Error analysis
Feedforward
Gradient methods
Inglés
Universidad de la República
COLIBRI
https://hdl.handle.net/20.500.12008/38774
Acceso abierto
Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)
Resumen: