Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit
Resumen:
Background: Healthcare-associated infections in intensive care units (ICUs) are associated with reservoirs such as sinks and drainage systems that sustain biofilms and disseminate Gram-negative bacteria. Between July 2021 and November 2022, an increase in PER-1 producing Pseudomonas aeruginosa (PaePER) was detected in the ICU of a university hospital in Uruguay. Aim: The objective was to describe the clinical epidemiology, confirm the environmental source and assess the impact of control measures. Methods: An outbreak investigation was conducted. Cases were ICU patients with at least one PaePER-positive sample; all other ICU patients were considered exposed. Data collection included clinical and laboratory surveillance, observation of healthcare processes and targeted environmental sampling of seven sinks. Isolates were identified by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS); antimicrobial susceptibility was assessed using VITEK2 (bioMerieux), E-test and disk diffusion; extended-spectrum β-lactamase production was evaluated by double-disk synergy and bla PER-1 was confirmed by polymerase chain reaction. Clonal relatedness was assessed by pulsed-field gel electrophoresis (PFGE). Control measures included dis continuation of patient room sink use, relocation of medication preparation, renewal of drainage systems and scheduled decontamination with a solution of 15% acetic acid. Findings: Among 1221 exposed patients, 31 were affected (attack rate: 2.8%): 25 infections and six colonisation episodes. Eighty-three clinical isolates were recovered, mainly from respiratory and blood samples. Isolates showed high resistance to ceftazidime, cefepime, ceftazidime/avibactam, ceftolozane/tazobactam and amikacin, with preserved susceptibility to carbapenems and cefiderocol. PaePER was recovered from four of seven sinks. PFGE confirmed a single ST309 clone. Conclusion: Sinks and drainage systems acted as the source of a PaePER outbreak. Targeted interventions rapidly interrupted transmission.
| 2026 | |
|
Pseudomonas aeruginosa Intensive care units Disease outbreaks Infection control Antimicrobial resistance |
|
| Inglés | |
| Universidad de la República | |
| COLIBRI | |
| https://hdl.handle.net/20.500.12008/54832 | |
| Acceso abierto | |
| Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) |
| _version_ | 1872865334012149760 |
|---|---|
| author | Araújo Pírez, L. |
| author2 | Papa-Ezdra, R. Outeda, M. Guzmán, R. Hernández, N. Méndez, G. Gadea, P. Moreira, M. Inchausti, A. Burghi, G. Seija, V. Vignoli, R. Albornoz Da Silva, H. |
| author2_role | author author author author author author author author author author author author |
| author_facet | Araújo Pírez, L. Papa-Ezdra, R. Outeda, M. Guzmán, R. Hernández, N. Méndez, G. Gadea, P. Moreira, M. Inchausti, A. Burghi, G. Seija, V. Vignoli, R. Albornoz Da Silva, H. |
| author_role | author |
| bitstream.checksum.fl_str_mv | 6429389a7df7277b72b7924fdc7d47a9 a006180e3f5b2ad0b88185d14284c0e0 00c6a163e62314ee9d2a181a90bf9e84 d62648cf14c1e37917d392ac87012955 888c5f5f071832bf0302b1c73b058db8 |
| bitstream.checksumAlgorithm.fl_str_mv | MD5 MD5 MD5 MD5 MD5 |
| bitstream.url.fl_str_mv | http://localhost:8080/xmlui/bitstream/20.500.12008/54832/5/license.txt http://localhost:8080/xmlui/bitstream/20.500.12008/54832/2/license_url http://localhost:8080/xmlui/bitstream/20.500.12008/54832/3/license_text http://localhost:8080/xmlui/bitstream/20.500.12008/54832/4/license_rdf http://localhost:8080/xmlui/bitstream/20.500.12008/54832/1/Containing+a+PER-1-producing+Pseudomonas+aeruginosa+outbreak+linked+to+sink+contamination+in+an+intensive+care+unit.pdf |
| collection | COLIBRI |
| dc.contributor.filiacion.none.fl_str_mv | Araújo Pírez L., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Unidad de Enfermedades Infecciosas Papa-Ezdra R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia Antibiótica Outeda M., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio Clínico Guzmán R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Medicina Preventiva y Social Hernández N., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Comité de Infecciones Hospitalarias Méndez G., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Centro de Tratamiento Intensivo Gadea P., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio Clínico Moreira M., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Comité de Infecciones Hospitalarias Inchausti A., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia Antibiótica Burghi G., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Centro de Tratamiento Intensivo Seija V., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio Clínico Vignoli R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia Antibiótica Albornoz Da Silva H., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Unidad de Enfermedades Infecciosas |
| dc.creator.none.fl_str_mv | Araújo Pírez, L. Papa-Ezdra, R. Outeda, M. Guzmán, R. Hernández, N. Méndez, G. Gadea, P. Moreira, M. Inchausti, A. Burghi, G. Seija, V. Vignoli, R. Albornoz Da Silva, H. |
| dc.date.accessioned.none.fl_str_mv | 2026-05-07T17:46:00Z |
| dc.date.available.none.fl_str_mv | 2026-05-07T17:46:00Z |
| dc.date.issued.none.fl_str_mv | 2026 |
| dc.description.abstract.none.fl_txt_mv | Background: Healthcare-associated infections in intensive care units (ICUs) are associated with reservoirs such as sinks and drainage systems that sustain biofilms and disseminate Gram-negative bacteria. Between July 2021 and November 2022, an increase in PER-1 producing Pseudomonas aeruginosa (PaePER) was detected in the ICU of a university hospital in Uruguay. Aim: The objective was to describe the clinical epidemiology, confirm the environmental source and assess the impact of control measures. Methods: An outbreak investigation was conducted. Cases were ICU patients with at least one PaePER-positive sample; all other ICU patients were considered exposed. Data collection included clinical and laboratory surveillance, observation of healthcare processes and targeted environmental sampling of seven sinks. Isolates were identified by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS); antimicrobial susceptibility was assessed using VITEK2 (bioMerieux), E-test and disk diffusion; extended-spectrum β-lactamase production was evaluated by double-disk synergy and bla PER-1 was confirmed by polymerase chain reaction. Clonal relatedness was assessed by pulsed-field gel electrophoresis (PFGE). Control measures included dis continuation of patient room sink use, relocation of medication preparation, renewal of drainage systems and scheduled decontamination with a solution of 15% acetic acid. Findings: Among 1221 exposed patients, 31 were affected (attack rate: 2.8%): 25 infections and six colonisation episodes. Eighty-three clinical isolates were recovered, mainly from respiratory and blood samples. Isolates showed high resistance to ceftazidime, cefepime, ceftazidime/avibactam, ceftolozane/tazobactam and amikacin, with preserved susceptibility to carbapenems and cefiderocol. PaePER was recovered from four of seven sinks. PFGE confirmed a single ST309 clone. Conclusion: Sinks and drainage systems acted as the source of a PaePER outbreak. Targeted interventions rapidly interrupted transmission. |
| dc.format.mimetype.es.fl_str_mv | application/pdf |
| dc.identifier.citation.es.fl_str_mv | ARAÚJO PÍREZ, L., PAPA-EZDRA, R., OUTEDA, M., y otros. Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit. Infect Prev Pract [en línea] 2026, 8. DOI: 10.1016/j.infpip.2026.100538 |
| dc.identifier.doi.none.fl_str_mv | 10.1016/j.infpip.2026.100538 |
| dc.identifier.uri.none.fl_str_mv | https://hdl.handle.net/20.500.12008/54832 |
| dc.language.iso.none.fl_str_mv | en eng |
| dc.relation.none.fl_str_mv | Infect Prev Pract. 8, 2026 |
| dc.rights.license.none.fl_str_mv | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) |
| dc.rights.none.fl_str_mv | info:eu-repo/semantics/openAccess |
| dc.source.none.fl_str_mv | reponame:COLIBRI instname:Universidad de la República instacron:Universidad de la República |
| dc.subject.es.fl_str_mv | Pseudomonas aeruginosa Intensive care units Disease outbreaks Infection control Antimicrobial resistance |
| dc.title.none.fl_str_mv | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| dc.type.es.fl_str_mv | Artículo |
| dc.type.none.fl_str_mv | info:eu-repo/semantics/article |
| dc.type.version.none.fl_str_mv | info:eu-repo/semantics/publishedVersion |
| description | Background: Healthcare-associated infections in intensive care units (ICUs) are associated with reservoirs such as sinks and drainage systems that sustain biofilms and disseminate Gram-negative bacteria. Between July 2021 and November 2022, an increase in PER-1 producing Pseudomonas aeruginosa (PaePER) was detected in the ICU of a university hospital in Uruguay. Aim: The objective was to describe the clinical epidemiology, confirm the environmental source and assess the impact of control measures. Methods: An outbreak investigation was conducted. Cases were ICU patients with at least one PaePER-positive sample; all other ICU patients were considered exposed. Data collection included clinical and laboratory surveillance, observation of healthcare processes and targeted environmental sampling of seven sinks. Isolates were identified by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS); antimicrobial susceptibility was assessed using VITEK2 (bioMerieux), E-test and disk diffusion; extended-spectrum β-lactamase production was evaluated by double-disk synergy and bla PER-1 was confirmed by polymerase chain reaction. Clonal relatedness was assessed by pulsed-field gel electrophoresis (PFGE). Control measures included dis continuation of patient room sink use, relocation of medication preparation, renewal of drainage systems and scheduled decontamination with a solution of 15% acetic acid. Findings: Among 1221 exposed patients, 31 were affected (attack rate: 2.8%): 25 infections and six colonisation episodes. Eighty-three clinical isolates were recovered, mainly from respiratory and blood samples. Isolates showed high resistance to ceftazidime, cefepime, ceftazidime/avibactam, ceftolozane/tazobactam and amikacin, with preserved susceptibility to carbapenems and cefiderocol. PaePER was recovered from four of seven sinks. PFGE confirmed a single ST309 clone. Conclusion: Sinks and drainage systems acted as the source of a PaePER outbreak. Targeted interventions rapidly interrupted transmission. |
| eu_rights_str_mv | openAccess |
| format | article |
| id | COLIBRI_4b031ac3b7ed1adadf170d6aeb4e998f |
| identifier_str_mv | ARAÚJO PÍREZ, L., PAPA-EZDRA, R., OUTEDA, M., y otros. Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit. Infect Prev Pract [en línea] 2026, 8. DOI: 10.1016/j.infpip.2026.100538 10.1016/j.infpip.2026.100538 |
| instacron_str | Universidad de la República |
| institution | Universidad de la República |
| instname_str | Universidad de la República |
| language | eng |
| language_invalid_str_mv | en |
| network_acronym_str | COLIBRI |
| network_name_str | COLIBRI |
| oai_identifier_str | oai:colibri.udelar.edu.uy:20.500.12008/54832 |
| publishDate | 2026 |
| reponame_str | COLIBRI |
| repository.mail.fl_str_mv | karina.camps@seciu.edu.uy |
| repository.name.fl_str_mv | COLIBRI - Universidad de la República |
| repository_id_str | 4771 |
| rights_invalid_str_mv | Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) |
| spelling | Araújo Pírez L., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Unidad de Enfermedades InfecciosasPapa-Ezdra R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia AntibióticaOuteda M., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio ClínicoGuzmán R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Medicina Preventiva y SocialHernández N., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Comité de Infecciones HospitalariasMéndez G., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Centro de Tratamiento IntensivoGadea P., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio ClínicoMoreira M., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Comité de Infecciones HospitalariasInchausti A., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia AntibióticaBurghi G., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Centro de Tratamiento IntensivoSeija V., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Área de Microbiología. Unidad de Laboratorio ClínicoVignoli R., Universidad de la República (Uruguay). Facultad de Medicina. Instituto de Higiene. Unidad Académica Bacteriología y Virología. Laboratorio de Resistencia AntibióticaAlbornoz Da Silva H., Universidad de la República (Uruguay). Facultad de Medicina. Hospital de Clínicas. Unidad de Enfermedades Infecciosas2026-05-07T17:46:00Z2026-05-07T17:46:00Z2026ARAÚJO PÍREZ, L., PAPA-EZDRA, R., OUTEDA, M., y otros. Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit. Infect Prev Pract [en línea] 2026, 8. DOI: 10.1016/j.infpip.2026.100538https://hdl.handle.net/20.500.12008/5483210.1016/j.infpip.2026.100538Background: Healthcare-associated infections in intensive care units (ICUs) are associated with reservoirs such as sinks and drainage systems that sustain biofilms and disseminate Gram-negative bacteria. Between July 2021 and November 2022, an increase in PER-1 producing Pseudomonas aeruginosa (PaePER) was detected in the ICU of a university hospital in Uruguay. Aim: The objective was to describe the clinical epidemiology, confirm the environmental source and assess the impact of control measures. Methods: An outbreak investigation was conducted. Cases were ICU patients with at least one PaePER-positive sample; all other ICU patients were considered exposed. Data collection included clinical and laboratory surveillance, observation of healthcare processes and targeted environmental sampling of seven sinks. Isolates were identified by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry (MALDI-TOF MS); antimicrobial susceptibility was assessed using VITEK2 (bioMerieux), E-test and disk diffusion; extended-spectrum β-lactamase production was evaluated by double-disk synergy and bla PER-1 was confirmed by polymerase chain reaction. Clonal relatedness was assessed by pulsed-field gel electrophoresis (PFGE). Control measures included dis continuation of patient room sink use, relocation of medication preparation, renewal of drainage systems and scheduled decontamination with a solution of 15% acetic acid. Findings: Among 1221 exposed patients, 31 were affected (attack rate: 2.8%): 25 infections and six colonisation episodes. Eighty-three clinical isolates were recovered, mainly from respiratory and blood samples. Isolates showed high resistance to ceftazidime, cefepime, ceftazidime/avibactam, ceftolozane/tazobactam and amikacin, with preserved susceptibility to carbapenems and cefiderocol. PaePER was recovered from four of seven sinks. PFGE confirmed a single ST309 clone. Conclusion: Sinks and drainage systems acted as the source of a PaePER outbreak. Targeted interventions rapidly interrupted transmission.Submitted by Haller Mariana (mhaller@higiene.edu.uy) on 2026-05-07T17:21:36Z No. of bitstreams: 2 license_rdf: 27293 bytes, checksum: d62648cf14c1e37917d392ac87012955 (MD5) Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit.pdf: 5005834 bytes, checksum: 888c5f5f071832bf0302b1c73b058db8 (MD5)Made available in DSpace by Luna Fabiana (fabiana.luna@seciu.edu.uy) on 2026-05-07T17:46:00Z (GMT). No. of bitstreams: 2 license_rdf: 27293 bytes, checksum: d62648cf14c1e37917d392ac87012955 (MD5) Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit.pdf: 5005834 bytes, checksum: 888c5f5f071832bf0302b1c73b058db8 (MD5) Previous issue date: 2026application/pdfenengInfect Prev Pract. 8, 2026Las obras depositadas en el Repositorio se rigen por la Ordenanza de los Derechos de la Propiedad Intelectual de la Universidad de la República.(Res. Nº 91 de C.D.C. de 8/III/1994 – D.O. 7/IV/1994) y por la Ordenanza del Repositorio Abierto de la Universidad de la República (Res. Nº 16 de C.D.C. de 07/10/2014)info:eu-repo/semantics/openAccessLicencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0)Pseudomonas aeruginosaIntensive care unitsDisease outbreaksInfection controlAntimicrobial resistanceContaining a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unitArtículoinfo:eu-repo/semantics/articleinfo:eu-repo/semantics/publishedVersionreponame:COLIBRIinstname:Universidad de la Repúblicainstacron:Universidad de la RepúblicaAraújo Pírez, L.Papa-Ezdra, R.Outeda, M.Guzmán, R.Hernández, N.Méndez, G.Gadea, P.Moreira, M.Inchausti, A.Burghi, G.Seija, V.Vignoli, R.Albornoz Da Silva, H.LICENSElicense.txtlicense.txttext/plain; charset=utf-84267http://localhost:8080/xmlui/bitstream/20.500.12008/54832/5/license.txt6429389a7df7277b72b7924fdc7d47a9MD55CC-LICENSElicense_urllicense_urltext/plain; charset=utf-850http://localhost:8080/xmlui/bitstream/20.500.12008/54832/2/license_urla006180e3f5b2ad0b88185d14284c0e0MD52license_textlicense_texttext/html; charset=utf-835935http://localhost:8080/xmlui/bitstream/20.500.12008/54832/3/license_text00c6a163e62314ee9d2a181a90bf9e84MD53license_rdflicense_rdfapplication/rdf+xml; charset=utf-827293http://localhost:8080/xmlui/bitstream/20.500.12008/54832/4/license_rdfd62648cf14c1e37917d392ac87012955MD54ORIGINALContaining a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit.pdfContaining a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit.pdfapplication/pdf5005834http://localhost:8080/xmlui/bitstream/20.500.12008/54832/1/Containing+a+PER-1-producing+Pseudomonas+aeruginosa+outbreak+linked+to+sink+contamination+in+an+intensive+care+unit.pdf888c5f5f071832bf0302b1c73b058db8MD5120.500.12008/548322026-05-07 14:46:00.522oai:colibri.udelar.edu.uy:20.500.12008/54832VGVybWlub3MgeSBjb25kaWNpb25lcyByZWxhdGl2YXMgYWwgZGVwb3NpdG8gZGUgb2JyYXMKCgpMYXMgb2JyYXMgZGVwb3NpdGFkYXMgZW4gZWwgUmVwb3NpdG9yaW8gc2UgcmlnZW4gcG9yIGxhIE9yZGVuYW56YSBkZSBsb3MgRGVyZWNob3MgZGUgbGEgUHJvcGllZGFkIEludGVsZWN0dWFsICBkZSBsYSBVbml2ZXJzaWRhZCBEZSBMYSBSZXDDumJsaWNhLiAoUmVzLiBOwrogOTEgZGUgQy5ELkMuIGRlIDgvSUlJLzE5OTQg4oCTIEQuTy4gNy9JVi8xOTk0KSB5ICBwb3IgbGEgT3JkZW5hbnphIGRlbCBSZXBvc2l0b3JpbyBBYmllcnRvIGRlIGxhIFVuaXZlcnNpZGFkIGRlIGxhIFJlcMO6YmxpY2EgKFJlcy4gTsK6IDE2IGRlIEMuRC5DLiBkZSAwNy8xMC8yMDE0KS4gCgpBY2VwdGFuZG8gZWwgYXV0b3IgZXN0b3MgdMOpcm1pbm9zIHkgY29uZGljaW9uZXMgZGUgZGVww7NzaXRvIGVuIENPTElCUkksIGxhIFVuaXZlcnNpZGFkIGRlIFJlcMO6YmxpY2EgcHJvY2VkZXLDoSBhOiAgCgphKSBhcmNoaXZhciBtw6FzIGRlIHVuYSBjb3BpYSBkZSBsYSBvYnJhIGVuIGxvcyBzZXJ2aWRvcmVzIGRlIGxhIFVuaXZlcnNpZGFkIGEgbG9zIGVmZWN0b3MgZGUgZ2FyYW50aXphciBhY2Nlc28sIHNlZ3VyaWRhZCB5IHByZXNlcnZhY2nDs24KYikgY29udmVydGlyIGxhIG9icmEgYSBvdHJvcyBmb3JtYXRvcyBzaSBmdWVyYSBuZWNlc2FyaW8gIHBhcmEgZmFjaWxpdGFyIHN1IHByZXNlcnZhY2nDs24geSBhY2Nlc2liaWxpZGFkIHNpbiBhbHRlcmFyIHN1IGNvbnRlbmlkby4KYykgcmVhbGl6YXIgbGEgY29tdW5pY2FjacOzbiBww7pibGljYSB5IGRpc3BvbmVyIGVsIGFjY2VzbyBsaWJyZSB5IGdyYXR1aXRvIGEgdHJhdsOpcyBkZSBJbnRlcm5ldCBtZWRpYW50ZSBsYSBwdWJsaWNhY2nDs24gZGUgbGEgb2JyYSBiYWpvIGxhIGxpY2VuY2lhIENyZWF0aXZlIENvbW1vbnMgc2VsZWNjaW9uYWRhIHBvciBlbCBwcm9waW8gYXV0b3IuCgoKRW4gY2FzbyBxdWUgZWwgYXV0b3IgaGF5YSBkaWZ1bmRpZG8geSBkYWRvIGEgcHVibGljaWRhZCBhIGxhIG9icmEgZW4gZm9ybWEgcHJldmlhLCAgcG9kcsOhIHNvbGljaXRhciB1biBwZXLDrW9kbyBkZSBlbWJhcmdvIHNvYnJlIGxhIGRpc3BvbmliaWxpZGFkIHDDumJsaWNhIGRlIGxhIG1pc21hLCBlbCBjdWFsIGNvbWVuemFyw6EgYSBwYXJ0aXIgZGUgbGEgYWNlcHRhY2nDs24gZGUgZXN0ZSBkb2N1bWVudG8geSBoYXN0YSBsYSBmZWNoYSBxdWUgaW5kaXF1ZSAuCgpFbCBhdXRvciBhc2VndXJhIHF1ZSBsYSBvYnJhIG5vIGluZnJpZ2UgbmluZ8O6biBkZXJlY2hvIHNvYnJlIHRlcmNlcm9zLCB5YSBzZWEgZGUgcHJvcGllZGFkIGludGVsZWN0dWFsIG8gY3VhbHF1aWVyIG90cm8uCgpFbCBhdXRvciBnYXJhbnRpemEgcXVlIHNpIGVsIGRvY3VtZW50byBjb250aWVuZSBtYXRlcmlhbGVzIGRlIGxvcyBjdWFsZXMgbm8gdGllbmUgbG9zIGRlcmVjaG9zIGRlIGF1dG9yLCAgaGEgb2J0ZW5pZG8gZWwgcGVybWlzbyBkZWwgcHJvcGlldGFyaW8gZGUgbG9zIGRlcmVjaG9zIGRlIGF1dG9yLCB5IHF1ZSBlc2UgbWF0ZXJpYWwgY3V5b3MgZGVyZWNob3Mgc29uIGRlIHRlcmNlcm9zIGVzdMOhIGNsYXJhbWVudGUgaWRlbnRpZmljYWRvIHkgcmVjb25vY2lkbyBlbiBlbCB0ZXh0byBvIGNvbnRlbmlkbyBkZWwgZG9jdW1lbnRvIGRlcG9zaXRhZG8gZW4gZWwgUmVwb3NpdG9yaW8uCgpFbiBvYnJhcyBkZSBhdXRvcsOtYSBtw7psdGlwbGUgL3NlIHByZXN1bWUvIHF1ZSBlbCBhdXRvciBkZXBvc2l0YW50ZSBkZWNsYXJhIHF1ZSBoYSByZWNhYmFkbyBlbCBjb25zZW50aW1pZW50byBkZSB0b2RvcyBsb3MgYXV0b3JlcyBwYXJhIHB1YmxpY2FybGEgZW4gZWwgUmVwb3NpdG9yaW8sIHNpZW5kbyDDqXN0ZSBlbCDDum5pY28gcmVzcG9uc2FibGUgZnJlbnRlIGEgY3VhbHF1aWVyIHRpcG8gZGUgcmVjbGFtYWNpw7NuIGRlIGxvcyBvdHJvcyBjb2F1dG9yZXMuCgpFbCBhdXRvciBzZXLDoSByZXNwb25zYWJsZSBkZWwgY29udGVuaWRvIGRlIGxvcyBkb2N1bWVudG9zIHF1ZSBkZXBvc2l0YS4gTGEgVURFTEFSIG5vIHNlcsOhIHJlc3BvbnNhYmxlIHBvciBsYXMgZXZlbnR1YWxlcyB2aW9sYWNpb25lcyBhbCBkZXJlY2hvIGRlIHByb3BpZWRhZCBpbnRlbGVjdHVhbCBlbiBxdWUgcHVlZGEgaW5jdXJyaXIgZWwgYXV0b3IuCgpBbnRlIGN1YWxxdWllciBkZW51bmNpYSBkZSB2aW9sYWNpw7NuIGRlIGRlcmVjaG9zIGRlIHByb3BpZWRhZCBpbnRlbGVjdHVhbCwgbGEgVURFTEFSICBhZG9wdGFyw6EgdG9kYXMgbGFzIG1lZGlkYXMgbmVjZXNhcmlhcyBwYXJhIGV2aXRhciBsYSBjb250aW51YWNpw7NuIGRlIGRpY2hhIGluZnJhY2Npw7NuLCBsYXMgcXVlIHBvZHLDoW4gaW5jbHVpciBlbCByZXRpcm8gZGVsIGFjY2VzbyBhIGxvcyBjb250ZW5pZG9zIHkvbyBtZXRhZGF0b3MgZGVsIGRvY3VtZW50byByZXNwZWN0aXZvLgoKTGEgb2JyYSBzZSBwb25kcsOhIGEgZGlzcG9zaWNpw7NuIGRlbCBww7pibGljbyBhIHRyYXbDqXMgZGUgbGFzIGxpY2VuY2lhcyBDcmVhdGl2ZSBDb21tb25zLCBlbCBhdXRvciBwb2Ryw6Egc2VsZWNjaW9uYXIgdW5hIGRlIGxhcyA2IGxpY2VuY2lhcyBkaXNwb25pYmxlczoKCgpBdHJpYnVjacOzbiAoQ0MgLSBCeSk6IFBlcm1pdGUgdXNhciBsYSBvYnJhIHkgZ2VuZXJhciBvYnJhcyBkZXJpdmFkYXMsIGluY2x1c28gY29uIGZpbmVzIGNvbWVyY2lhbGVzLCBzaWVtcHJlIHF1ZSBzZSByZWNvbm96Y2EgYWwgYXV0b3IuCgpBdHJpYnVjacOzbiDigJMgQ29tcGFydGlyIElndWFsIChDQyAtIEJ5LVNBKTogUGVybWl0ZSB1c2FyIGxhIG9icmEgeSBnZW5lcmFyIG9icmFzIGRlcml2YWRhcywgaW5jbHVzbyBjb24gZmluZXMgY29tZXJjaWFsZXMsIHBlcm8gbGEgZGlzdHJpYnVjacOzbiBkZSBsYXMgb2JyYXMgZGVyaXZhZGFzIGRlYmUgaGFjZXJzZSBtZWRpYW50ZSB1bmEgbGljZW5jaWEgaWTDqW50aWNhIGEgbGEgZGUgbGEgb2JyYSBvcmlnaW5hbCwgcmVjb25vY2llbmRvIGEgbG9zIGF1dG9yZXMuCgpBdHJpYnVjacOzbiDigJMgTm8gQ29tZXJjaWFsIChDQyAtIEJ5LU5DKTogUGVybWl0ZSB1c2FyIGxhIG9icmEgeSBnZW5lcmFyIG9icmFzIGRlcml2YWRhcywgc2llbXByZSB5IGN1YW5kbyBlc29zIHVzb3Mgbm8gdGVuZ2FuIGZpbmVzIGNvbWVyY2lhbGVzLCByZWNvbm9jaWVuZG8gYWwgYXV0b3IuCgpBdHJpYnVjacOzbiDigJMgU2luIERlcml2YWRhcyAoQ0MgLSBCeS1ORCk6IFBlcm1pdGUgZWwgdXNvIGRlIGxhIG9icmEsIGluY2x1c28gY29uIGZpbmVzIGNvbWVyY2lhbGVzLCBwZXJvIG5vIHNlIHBlcm1pdGUgZ2VuZXJhciBvYnJhcyBkZXJpdmFkYXMsIGRlYmllbmRvIHJlY29ub2NlciBhbCBhdXRvci4KCkF0cmlidWNpw7NuIOKAkyBObyBDb21lcmNpYWwg4oCTIENvbXBhcnRpciBJZ3VhbCAoQ0Mg4oCTIEJ5LU5DLVNBKTogUGVybWl0ZSB1c2FyIGxhIG9icmEgeSBnZW5lcmFyIG9icmFzIGRlcml2YWRhcywgc2llbXByZSB5IGN1YW5kbyBlc29zIHVzb3Mgbm8gdGVuZ2FuIGZpbmVzIGNvbWVyY2lhbGVzIHkgbGEgZGlzdHJpYnVjacOzbiBkZSBsYXMgb2JyYXMgZGVyaXZhZGFzIHNlIGhhZ2EgbWVkaWFudGUgbGljZW5jaWEgaWTDqW50aWNhIGEgbGEgZGUgbGEgb2JyYSBvcmlnaW5hbCwgcmVjb25vY2llbmRvIGEgbG9zIGF1dG9yZXMuCgpBdHJpYnVjacOzbiDigJMgTm8gQ29tZXJjaWFsIOKAkyBTaW4gRGVyaXZhZGFzIChDQyAtIEJ5LU5DLU5EKTogUGVybWl0ZSB1c2FyIGxhIG9icmEsIHBlcm8gbm8gc2UgcGVybWl0ZSBnZW5lcmFyIG9icmFzIGRlcml2YWRhcyB5IG5vIHNlIHBlcm1pdGUgdXNvIGNvbiBmaW5lcyBjb21lcmNpYWxlcywgZGViaWVuZG8gcmVjb25vY2VyIGFsIGF1dG9yLgoKTG9zIHVzb3MgcHJldmlzdG9zIGVuIGxhcyBsaWNlbmNpYXMgaW5jbHV5ZW4gbGEgZW5hamVuYWNpw7NuLCByZXByb2R1Y2Npw7NuLCBjb211bmljYWNpw7NuLCBwdWJsaWNhY2nDs24sIGRpc3RyaWJ1Y2nDs24geSBwdWVzdGEgYSBkaXNwb3NpY2nDs24gZGVsIHDDumJsaWNvLiBMYSBjcmVhY2nDs24gZGUgb2JyYXMgZGVyaXZhZGFzIGluY2x1eWUgbGEgYWRhcHRhY2nDs24sIHRyYWR1Y2Npw7NuIHkgZWwgcmVtaXguCgpDdWFuZG8gc2Ugc2VsZWNjaW9uZSB1bmEgbGljZW5jaWEgcXVlIGhhYmlsaXRlIHVzb3MgY29tZXJjaWFsZXMsIGVsIGRlcMOzc2l0byBkZWJlcsOhIHNlciBhY29tcGHDsWFkbyBkZWwgYXZhbCBkZWwgamVyYXJjYSBtw6F4aW1vIGRlbCBTZXJ2aWNpbyBjb3JyZXNwb25kaWVudGUuCg==Institucionalhttps://www.colibri.udelar.edu.uyUniversidad públicahttps://udelar.edu.uy/https://www.colibri.udelar.edu.uy/oai/requestkarina.camps@seciu.edu.uyUruguayopendoar:47712026-05-07T17:46COLIBRI - Universidad de la Repúblicafalse |
| spellingShingle | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit Araújo Pírez, L. Pseudomonas aeruginosa Intensive care units Disease outbreaks Infection control Antimicrobial resistance |
| status_str | publishedVersion |
| title | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| title_full | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| title_fullStr | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| title_full_unstemmed | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| title_short | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| title_sort | Containing a PER-1-producing Pseudomonas aeruginosa outbreak linked to sink contamination in an intensive care unit |
| topic | Pseudomonas aeruginosa Intensive care units Disease outbreaks Infection control Antimicrobial resistance |
| url | https://hdl.handle.net/20.500.12008/54832 |