Calibration of the penalties of the operating restrictions of cascade hydroelectric plants in Uruguay and their consequences on the cost of supplying national demand.
Resumen:
A methodology is presented for the calibration of penalties to represent the operating restrictions of a chain of hydroelectric plants. The restrictions considered are those of lower and upper level of operation and those of minimum delivered flow.
| 2024 | |
|
Multi Objective Optimization Hydroelectric operation restrictions |
|
| Inglés | |
| Universidad de la República | |
| COLIBRI | |
|
https://doity.com.br/anais/9elaee/trabalho/351195
https://hdl.handle.net/20.500.12008/50481 |
|
| Acceso abierto | |
| Licencia Creative Commons Atribución - No Comercial - Sin Derivadas (CC - By-NC-ND 4.0) |